2 lines
352 KiB
JSON
2 lines
352 KiB
JSON
{"table":{"alias":"","comment":"项目划分表是用于存储工程项目划分树状数据。内部包含安装工程项目划分,建筑工程项目划分,线路项目划分,工程分部分项。查询示例: SELECT Sum_Price FROM ProjectDivision WHERE Name = 'findname'。","fields":[{"alias":"","comment":"","name":"_id","type":"VARCHAR"},{"alias":"专业类型","comment":"专业类型,字段值有变电安装、变电建筑、线路等。变电安装等于安装工程,变电建筑等于建筑工程,线路等于安装工程。","name":"ProfessionalType","type":"VARCHAR"},{"alias":"拆除人工调差系数","comment":"此项目划分下拆除人工调差系数","name":"Demolition_Manual_Adjustment_Coefficient","type":"REAL"},{"alias":"编号,代码,代号","comment":"项目划分代码","name":"Code","type":"VARCHAR"},{"alias":"单位","comment":"项目划分单位","name":"Unit","type":"VARCHAR"},{"alias":"取费表","comment":"项目划分的取费表,此项目划分选用的取费表","name":"FeeCollectionTableName","type":"VARCHAR"},{"alias":"合价,合计","comment":"项目划分合价,分部分项费用","name":"Sum_Price","type":"REAL"},{"alias":"项目名,名称","comment":"项目名称","name":"Name","type":"VARCHAR"},{"alias":"备注,说明","comment":"备注","name":"Remarks","type":"VARCHAR"},{"alias":"项目序号,序号,序列号","comment":"项目划分序号","name":"SerialNumber","type":"VARCHAR"},{"alias":"拆除人工调差系数","comment":"此项目划分下拆除人工调差系数","name":"Demolition_Manual_Adjustment_Coefficient","type":"REAL"},{"alias":"拆除机械调差系数","comment":"此项目划分下拆除机械调差系数","name":"Demolition_Mechanical_Adjustment_Coefficient","type":"REAL"},{"alias":"拆除材料调差系数","comment":"此项目划分下拆除材料调差系数","name":"Demolition_Material_Adjustment_Coefficient","type":"REAL"},{"alias":"数目,数量,个数","comment":"项目划分数量","name":"Quantity","type":"REAL"},{"alias":"拆除机械调差系数","comment":"此项目划分下拆除机械调差系数","name":"Demolition_Mechanical_Adjustment_Coefficient","type":"REAL"},{"alias":"拆除材料调差系数","comment":"此项目划分下拆除材料调差系数","name":"Demolition_Material_Adjustment_Coefficient","type":"REAL"},{"alias":"译码,编码","comment":"项目划分编码","name":"Encoding","type":"VARCHAR"},{"alias":"公式,计算式,表达式","comment":"项目划分计算式","name":"CalculationFormula","type":"VARCHAR"},{"alias":"费用利率,费率","comment":"项目划分费率","name":"Rate","type":"REAL"},{"alias":"","comment":"","name":"费用编码","type":"VARCHAR"},{"alias":"路径,项目全路径","comment":"项目划分层级全路径","name":"Path","type":"VARCHAR"},{"alias":"","comment":"","name":"nodeType","type":"VARCHAR"},{"alias":"","comment":"","name":"parentId","type":"VARCHAR"},{"alias":"","comment":"","name":"relTbId","type":"VARCHAR"}],"name":"ProjectDivision","records":[{"_id":"{1DD3426E-A17E-4FC9-B7B5-22543997388C}","nodeType":"项目划分","parentId":"","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"建筑工程","备注":"","序号":"","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21810000000","路径":"建筑工程"},{"_id":"{CECBFEE2-0081-45F6-8BDC-08CF271B43A1}","nodeType":"项目划分","parentId":"{1DD3426E-A17E-4FC9-B7B5-22543997388C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"ZYSC","单位":"","取费表":"","合价":"0","名称":"主要生产工程","备注":"","序号":"一","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811000000","路径":"建筑工程/主要生产工程"},{"_id":"{5A29FF14-403D-4940-B436-D62A907FD440}","nodeType":"项目划分","parentId":"{CECBFEE2-0081-45F6-8BDC-08CF271B43A1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"主要生产建筑","备注":"","序号":"1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811100000","路径":"建筑工程/主要生产工程/主要生产建筑"},{"_id":"{B82F29FB-A485-485A-83BE-8A1D4DE25D24}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"主控通信楼","备注":"","序号":"1.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811101000","路径":"建筑工程/主要生产工程/主要生产建筑/主控通信楼"},{"_id":"{92BC37A4-B85E-427E-89F1-94063148586B}","nodeType":"项目划分","parentId":"{B82F29FB-A485-485A-83BE-8A1D4DE25D24}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.1.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811101100","路径":"建筑工程/主要生产工程/主要生产建筑/主控通信楼/一般土建"},{"_id":"{51E88581-873C-4897-A4F8-898524C9859F}","nodeType":"项目划分","parentId":"{B82F29FB-A485-485A-83BE-8A1D4DE25D24}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"给排水","备注":"","序号":"1.1.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811101200","路径":"建筑工程/主要生产工程/主要生产建筑/主控通信楼/给排水"},{"_id":"{2170A937-A7EC-4D5D-9EA3-DABD5BBD93C9}","nodeType":"项目划分","parentId":"{B82F29FB-A485-485A-83BE-8A1D4DE25D24}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.1.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811101300","路径":"建筑工程/主要生产工程/主要生产建筑/主控通信楼/采暖、通风及空调"},{"_id":"{BD16CA2F-9DA7-4E0D-B13E-BA0989C7C4AC}","nodeType":"项目划分","parentId":"{B82F29FB-A485-485A-83BE-8A1D4DE25D24}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.1.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811101400","路径":"建筑工程/主要生产工程/主要生产建筑/主控通信楼/照明"},{"_id":"{EBE84A1A-3E78-446E-943D-1A031BFE70BE}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"1000kV继电器室","备注":"","序号":"1.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811102000","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV继电器室"},{"_id":"{ECB52D4A-B099-41FC-9776-B8805572AA15}","nodeType":"项目划分","parentId":"{EBE84A1A-3E78-446E-943D-1A031BFE70BE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.2.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811102100","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV继电器室/一般土建"},{"_id":"{EB6F984C-84A5-47EA-B7B2-5590C9D1DD9C}","nodeType":"项目划分","parentId":"{EBE84A1A-3E78-446E-943D-1A031BFE70BE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.2.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811102200","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV继电器室/采暖、通风及空调"},{"_id":"{52CD9C8E-65B0-4128-A9DE-E7C2952BD400}","nodeType":"项目划分","parentId":"{EBE84A1A-3E78-446E-943D-1A031BFE70BE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.2.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811102300","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV继电器室/照明"},{"_id":"{69348571-38C4-4905-AD3A-FF69BC955287}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"750kV继电器室","备注":"","序号":"1.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811103000","路径":"建筑工程/主要生产工程/主要生产建筑/750kV继电器室"},{"_id":"{AE35645F-751E-4968-8ED5-A085C6A492BA}","nodeType":"项目划分","parentId":"{69348571-38C4-4905-AD3A-FF69BC955287}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811103100","路径":"建筑工程/主要生产工程/主要生产建筑/750kV继电器室/一般土建"},{"_id":"{8A8EB747-8D8D-4993-89BA-32E251EF6F0B}","nodeType":"项目划分","parentId":"{69348571-38C4-4905-AD3A-FF69BC955287}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811103200","路径":"建筑工程/主要生产工程/主要生产建筑/750kV继电器室/采暖、通风及空调"},{"_id":"{4A2DAA36-5801-4945-BDF0-69B7CC6097DA}","nodeType":"项目划分","parentId":"{69348571-38C4-4905-AD3A-FF69BC955287}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811103300","路径":"建筑工程/主要生产工程/主要生产建筑/750kV继电器室/照明"},{"_id":"{342B8E2B-2B61-4469-B925-1C5316A6D653}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"660kV继电器室","备注":"","序号":"1.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811104000","路径":"建筑工程/主要生产工程/主要生产建筑/660kV继电器室"},{"_id":"{FA942891-B396-4A68-BF93-4B19BAF9F4F4}","nodeType":"项目划分","parentId":"{342B8E2B-2B61-4469-B925-1C5316A6D653}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.4.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811104100","路径":"建筑工程/主要生产工程/主要生产建筑/660kV继电器室/一般土建"},{"_id":"{A0C14440-1507-437B-B8A7-4FB5D3C808A4}","nodeType":"项目划分","parentId":"{342B8E2B-2B61-4469-B925-1C5316A6D653}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.4.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811104200","路径":"建筑工程/主要生产工程/主要生产建筑/660kV继电器室/采暖、通风及空调"},{"_id":"{C91590CD-D1DA-4A6B-B281-7EA18E914443}","nodeType":"项目划分","parentId":"{342B8E2B-2B61-4469-B925-1C5316A6D653}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.4.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811104300","路径":"建筑工程/主要生产工程/主要生产建筑/660kV继电器室/照明"},{"_id":"{9F3187A1-B257-4839-A21F-D6C34A08E729}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"500kV继电器室","备注":"","序号":"1.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811105000","路径":"建筑工程/主要生产工程/主要生产建筑/500kV继电器室"},{"_id":"{4373442D-E1C3-4BDE-A968-E88545174A54}","nodeType":"项目划分","parentId":"{9F3187A1-B257-4839-A21F-D6C34A08E729}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.5.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811105100","路径":"建筑工程/主要生产工程/主要生产建筑/500kV继电器室/一般土建"},{"_id":"{D9170426-0CBA-460E-A076-2379331701B8}","nodeType":"项目划分","parentId":"{9F3187A1-B257-4839-A21F-D6C34A08E729}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.5.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811105200","路径":"建筑工程/主要生产工程/主要生产建筑/500kV继电器室/采暖、通风及空调"},{"_id":"{32D1C915-F0C5-4D44-8088-62E3C0FC71E5}","nodeType":"项目划分","parentId":"{9F3187A1-B257-4839-A21F-D6C34A08E729}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.5.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811105300","路径":"建筑工程/主要生产工程/主要生产建筑/500kV继电器室/照明"},{"_id":"{D3726E46-E5D4-41FA-BE3E-ED7BFB48D543}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"330kV继电器室","备注":"","序号":"1.6","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811106000","路径":"建筑工程/主要生产工程/主要生产建筑/330kV继电器室"},{"_id":"{D6A4A53D-48A2-4D57-B297-C4CD5E7C309C}","nodeType":"项目划分","parentId":"{D3726E46-E5D4-41FA-BE3E-ED7BFB48D543}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.6.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811106100","路径":"建筑工程/主要生产工程/主要生产建筑/330kV继电器室/一般土建"},{"_id":"{C5A94BD1-2089-4C7F-99DC-3D9D72C9A97B}","nodeType":"项目划分","parentId":"{D3726E46-E5D4-41FA-BE3E-ED7BFB48D543}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.6.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811106200","路径":"建筑工程/主要生产工程/主要生产建筑/330kV继电器室/采暖、通风及空调"},{"_id":"{4AB094F9-FFF4-4A88-85B9-53EC1AD6AAA7}","nodeType":"项目划分","parentId":"{D3726E46-E5D4-41FA-BE3E-ED7BFB48D543}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.6.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811106300","路径":"建筑工程/主要生产工程/主要生产建筑/330kV继电器室/照明"},{"_id":"{F4DBFF6A-0FB8-4E09-B00F-61EEB72184E4}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"220kV继电器室","备注":"","序号":"1.7","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811107000","路径":"建筑工程/主要生产工程/主要生产建筑/220kV继电器室"},{"_id":"{1DBD2AC8-2B29-4B23-B8BB-8E4E08254682}","nodeType":"项目划分","parentId":"{F4DBFF6A-0FB8-4E09-B00F-61EEB72184E4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.7.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811107100","路径":"建筑工程/主要生产工程/主要生产建筑/220kV继电器室/一般土建"},{"_id":"{C122029B-9B3F-4936-A8EF-ED828292FB29}","nodeType":"项目划分","parentId":"{F4DBFF6A-0FB8-4E09-B00F-61EEB72184E4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.7.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811107200","路径":"建筑工程/主要生产工程/主要生产建筑/220kV继电器室/采暖、通风及空调"},{"_id":"{DAC2ADF8-BB14-441A-8547-34A88EA5E35C}","nodeType":"项目划分","parentId":"{F4DBFF6A-0FB8-4E09-B00F-61EEB72184E4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.7.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811107300","路径":"建筑工程/主要生产工程/主要生产建筑/220kV继电器室/照明"},{"_id":"{4035EB94-9E4E-440C-AA39-589F24CBF1E7}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"110kV继电器室","备注":"","序号":"1.8","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811108000","路径":"建筑工程/主要生产工程/主要生产建筑/110kV继电器室"},{"_id":"{937A3E22-B43C-42A9-8A3B-FC1D3AF0A75D}","nodeType":"项目划分","parentId":"{4035EB94-9E4E-440C-AA39-589F24CBF1E7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.8.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811108100","路径":"建筑工程/主要生产工程/主要生产建筑/110kV继电器室/一般土建"},{"_id":"{9C6B48A6-FE60-472F-94B7-E3006AD13CCB}","nodeType":"项目划分","parentId":"{4035EB94-9E4E-440C-AA39-589F24CBF1E7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.8.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811108200","路径":"建筑工程/主要生产工程/主要生产建筑/110kV继电器室/采暖、通风及空调"},{"_id":"{5F19BE4C-F9F6-4A72-9E2F-C7BF1F29E952}","nodeType":"项目划分","parentId":"{4035EB94-9E4E-440C-AA39-589F24CBF1E7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.8.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811108300","路径":"建筑工程/主要生产工程/主要生产建筑/110kV继电器室/照明"},{"_id":"{A3F23AC1-8554-4B8D-A341-476F23033DB4}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"66kV继电器室","备注":"","序号":"1.9","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811109000","路径":"建筑工程/主要生产工程/主要生产建筑/66kV继电器室"},{"_id":"{4187ABC4-1B5E-49B9-B297-C55A9C42BCA8}","nodeType":"项目划分","parentId":"{A3F23AC1-8554-4B8D-A341-476F23033DB4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.9.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811109100","路径":"建筑工程/主要生产工程/主要生产建筑/66kV继电器室/一般土建"},{"_id":"{FB1DA58F-5438-4DF3-AF81-F096C4342812}","nodeType":"项目划分","parentId":"{A3F23AC1-8554-4B8D-A341-476F23033DB4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.9.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811109200","路径":"建筑工程/主要生产工程/主要生产建筑/66kV继电器室/采暖、通风及空调"},{"_id":"{9AB9AE38-3F8A-4F6E-BD9A-3753247434FC}","nodeType":"项目划分","parentId":"{A3F23AC1-8554-4B8D-A341-476F23033DB4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.9.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811109300","路径":"建筑工程/主要生产工程/主要生产建筑/66kV继电器室/照明"},{"_id":"{404808A3-3A3D-48AB-880F-B10A354D6309}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"35kV继电器室","备注":"","序号":"1.10","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811110000","路径":"建筑工程/主要生产工程/主要生产建筑/35kV继电器室"},{"_id":"{B2F5D285-9384-415A-B57D-89A35B978E66}","nodeType":"项目划分","parentId":"{404808A3-3A3D-48AB-880F-B10A354D6309}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.10.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811110100","路径":"建筑工程/主要生产工程/主要生产建筑/35kV继电器室/一般土建"},{"_id":"{2D5E07C9-142E-4BFA-996C-9F6615145897}","nodeType":"项目划分","parentId":"{404808A3-3A3D-48AB-880F-B10A354D6309}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.10.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811110200","路径":"建筑工程/主要生产工程/主要生产建筑/35kV继电器室/采暖、通风及空调"},{"_id":"{5D13FF0C-9B92-4950-B7E6-16A1A4B197AA}","nodeType":"项目划分","parentId":"{404808A3-3A3D-48AB-880F-B10A354D6309}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.10.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811110300","路径":"建筑工程/主要生产工程/主要生产建筑/35kV继电器室/照明"},{"_id":"{B5EB56BA-2002-49E0-906F-CAC6DF78269A}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"20kV继电器室","备注":"","序号":"1.11","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811111000","路径":"建筑工程/主要生产工程/主要生产建筑/20kV继电器室"},{"_id":"{E8508A59-E2F0-40ED-855D-9E092CE40648}","nodeType":"项目划分","parentId":"{B5EB56BA-2002-49E0-906F-CAC6DF78269A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.11.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811111100","路径":"建筑工程/主要生产工程/主要生产建筑/20kV继电器室/一般土建"},{"_id":"{987301F9-7B98-4747-902E-770904FE3F9E}","nodeType":"项目划分","parentId":"{B5EB56BA-2002-49E0-906F-CAC6DF78269A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.11.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811111200","路径":"建筑工程/主要生产工程/主要生产建筑/20kV继电器室/采暖、通风及空调"},{"_id":"{4E059C06-0484-4CD0-8149-A99FFE598AEB}","nodeType":"项目划分","parentId":"{B5EB56BA-2002-49E0-906F-CAC6DF78269A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.11.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811111300","路径":"建筑工程/主要生产工程/主要生产建筑/20kV继电器室/照明"},{"_id":"{06A77859-468F-4573-8B9E-21267EC64458}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"10kV继电器室","备注":"","序号":"1.12","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811112000","路径":"建筑工程/主要生产工程/主要生产建筑/10kV继电器室"},{"_id":"{90454C5D-4772-4698-B04F-DE86CF0CDA01}","nodeType":"项目划分","parentId":"{06A77859-468F-4573-8B9E-21267EC64458}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.12.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811112100","路径":"建筑工程/主要生产工程/主要生产建筑/10kV继电器室/一般土建"},{"_id":"{BAEA98B6-B750-47AA-BDDE-716E664FE0C2}","nodeType":"项目划分","parentId":"{06A77859-468F-4573-8B9E-21267EC64458}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.12.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811112200","路径":"建筑工程/主要生产工程/主要生产建筑/10kV继电器室/采暖、通风及空调"},{"_id":"{3642888B-7B88-4085-8B23-24B01537B42E}","nodeType":"项目划分","parentId":"{06A77859-468F-4573-8B9E-21267EC64458}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.12.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811112300","路径":"建筑工程/主要生产工程/主要生产建筑/10kV继电器室/照明"},{"_id":"{204CBF73-8D88-475C-A502-03CB81E2B81A}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"站用配电装置室","备注":"","序号":"1.13","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811113000","路径":"建筑工程/主要生产工程/主要生产建筑/站用配电装置室"},{"_id":"{F7CC3E57-8EC3-41B7-9101-E55179A0B9D2}","nodeType":"项目划分","parentId":"{204CBF73-8D88-475C-A502-03CB81E2B81A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.13.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811113100","路径":"建筑工程/主要生产工程/主要生产建筑/站用配电装置室/一般土建"},{"_id":"{66C06D21-2BD7-4E19-A3BB-2E623C906DFF}","nodeType":"项目划分","parentId":"{204CBF73-8D88-475C-A502-03CB81E2B81A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.13.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811113200","路径":"建筑工程/主要生产工程/主要生产建筑/站用配电装置室/采暖、通风及空调"},{"_id":"{DBE70C9A-DC0B-446D-A39D-F7AFA8970675}","nodeType":"项目划分","parentId":"{204CBF73-8D88-475C-A502-03CB81E2B81A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.13.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811113300","路径":"建筑工程/主要生产工程/主要生产建筑/站用配电装置室/照明"},{"_id":"{48E03401-AEAB-4580-AC9E-10038B375C64}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"1000kV站用配电装置室","备注":"","序号":"1.14","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811114000","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV站用配电装置室"},{"_id":"{4DD92DCF-6BF2-47B8-B48F-9373D50BAE2A}","nodeType":"项目划分","parentId":"{48E03401-AEAB-4580-AC9E-10038B375C64}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.14.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811114100","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV站用配电装置室/一般土建"},{"_id":"{71F76425-E611-4117-89EC-27A273610E73}","nodeType":"项目划分","parentId":"{48E03401-AEAB-4580-AC9E-10038B375C64}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.14.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811114200","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV站用配电装置室/采暖、通风及空调"},{"_id":"{10134137-9F53-46D0-80CD-42061080F261}","nodeType":"项目划分","parentId":"{48E03401-AEAB-4580-AC9E-10038B375C64}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.14.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811114300","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV站用配电装置室/照明"},{"_id":"{0C581088-D80D-46B6-AEC4-E77025B5F9EA}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"750kV站用配电装置室","备注":"","序号":"1.15","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811115000","路径":"建筑工程/主要生产工程/主要生产建筑/750kV站用配电装置室"},{"_id":"{6456FD19-82F3-417A-9395-BD73002752E1}","nodeType":"项目划分","parentId":"{0C581088-D80D-46B6-AEC4-E77025B5F9EA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.15.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811115100","路径":"建筑工程/主要生产工程/主要生产建筑/750kV站用配电装置室/一般土建"},{"_id":"{8F602463-899C-4D05-83EF-53C833489B36}","nodeType":"项目划分","parentId":"{0C581088-D80D-46B6-AEC4-E77025B5F9EA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.15.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811115200","路径":"建筑工程/主要生产工程/主要生产建筑/750kV站用配电装置室/采暖、通风及空调"},{"_id":"{83EB1879-1C83-4041-9F0D-8752C339A195}","nodeType":"项目划分","parentId":"{0C581088-D80D-46B6-AEC4-E77025B5F9EA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.15.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811115300","路径":"建筑工程/主要生产工程/主要生产建筑/750kV站用配电装置室/照明"},{"_id":"{370AAB4D-9A6D-4FF4-B14B-7580C52AE3E9}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"660kV站用配电装置室","备注":"","序号":"1.16","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811116000","路径":"建筑工程/主要生产工程/主要生产建筑/660kV站用配电装置室"},{"_id":"{15D4F65D-5123-418D-925C-94E23C66DD35}","nodeType":"项目划分","parentId":"{370AAB4D-9A6D-4FF4-B14B-7580C52AE3E9}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.16.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811116100","路径":"建筑工程/主要生产工程/主要生产建筑/660kV站用配电装置室/一般土建"},{"_id":"{BC28E132-5A3D-4F91-B69B-BE15EFD2727E}","nodeType":"项目划分","parentId":"{370AAB4D-9A6D-4FF4-B14B-7580C52AE3E9}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.16.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811116200","路径":"建筑工程/主要生产工程/主要生产建筑/660kV站用配电装置室/采暖、通风及空调"},{"_id":"{63B41DCA-F064-4BB3-BE94-2AB6CD8BA781}","nodeType":"项目划分","parentId":"{370AAB4D-9A6D-4FF4-B14B-7580C52AE3E9}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.16.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811116300","路径":"建筑工程/主要生产工程/主要生产建筑/660kV站用配电装置室/照明"},{"_id":"{7CF3B32B-20B3-4F7D-A57E-2D42E8489111}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"500kV站用配电装置室","备注":"","序号":"1.17","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811117000","路径":"建筑工程/主要生产工程/主要生产建筑/500kV站用配电装置室"},{"_id":"{012237C6-C19A-443A-A30A-FCAF9F8416F5}","nodeType":"项目划分","parentId":"{7CF3B32B-20B3-4F7D-A57E-2D42E8489111}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.17.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811117100","路径":"建筑工程/主要生产工程/主要生产建筑/500kV站用配电装置室/一般土建"},{"_id":"{32360FB5-7E55-40A0-AEEA-3275624948D0}","nodeType":"项目划分","parentId":"{7CF3B32B-20B3-4F7D-A57E-2D42E8489111}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.17.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811117200","路径":"建筑工程/主要生产工程/主要生产建筑/500kV站用配电装置室/采暖、通风及空调"},{"_id":"{7F50526D-E7E7-493C-A201-9E20133B0B58}","nodeType":"项目划分","parentId":"{7CF3B32B-20B3-4F7D-A57E-2D42E8489111}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.17.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811117300","路径":"建筑工程/主要生产工程/主要生产建筑/500kV站用配电装置室/照明"},{"_id":"{C0A83497-BB74-453B-B68F-52D8F987970B}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"330kV站用配电装置室","备注":"","序号":"1.18","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811118000","路径":"建筑工程/主要生产工程/主要生产建筑/330kV站用配电装置室"},{"_id":"{6D8A4072-770E-4388-8220-3657DF6A273D}","nodeType":"项目划分","parentId":"{C0A83497-BB74-453B-B68F-52D8F987970B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.18.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811118100","路径":"建筑工程/主要生产工程/主要生产建筑/330kV站用配电装置室/一般土建"},{"_id":"{9FEF5A9B-5F2D-4AA4-9EDF-109EC3CF0E5F}","nodeType":"项目划分","parentId":"{C0A83497-BB74-453B-B68F-52D8F987970B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.18.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811118200","路径":"建筑工程/主要生产工程/主要生产建筑/330kV站用配电装置室/采暖、通风及空调"},{"_id":"{FFE629AB-F222-4A1C-BFF9-3A0837485131}","nodeType":"项目划分","parentId":"{C0A83497-BB74-453B-B68F-52D8F987970B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.18.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811118300","路径":"建筑工程/主要生产工程/主要生产建筑/330kV站用配电装置室/照明"},{"_id":"{7C609329-6449-4760-B719-6672DE6F266E}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"220kV站用配电装置室","备注":"","序号":"1.19","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811119000","路径":"建筑工程/主要生产工程/主要生产建筑/220kV站用配电装置室"},{"_id":"{D73C9B15-EAB5-48E2-8114-A49890D5AD89}","nodeType":"项目划分","parentId":"{7C609329-6449-4760-B719-6672DE6F266E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.19.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811119100","路径":"建筑工程/主要生产工程/主要生产建筑/220kV站用配电装置室/一般土建"},{"_id":"{9993E102-FE26-4858-8014-789C8467F0A1}","nodeType":"项目划分","parentId":"{7C609329-6449-4760-B719-6672DE6F266E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.19.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811119200","路径":"建筑工程/主要生产工程/主要生产建筑/220kV站用配电装置室/采暖、通风及空调"},{"_id":"{7F7255BB-2196-47CB-97C2-136FCB1CAA55}","nodeType":"项目划分","parentId":"{7C609329-6449-4760-B719-6672DE6F266E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.19.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811119300","路径":"建筑工程/主要生产工程/主要生产建筑/220kV站用配电装置室/照明"},{"_id":"{D59DD5FE-D445-4356-88A3-A17A7F73AD60}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"110kV站用配电装置室","备注":"","序号":"1.20","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811120000","路径":"建筑工程/主要生产工程/主要生产建筑/110kV站用配电装置室"},{"_id":"{CAA1CE03-EE6E-4528-97FF-54FD0FE3368A}","nodeType":"项目划分","parentId":"{D59DD5FE-D445-4356-88A3-A17A7F73AD60}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.20.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811120100","路径":"建筑工程/主要生产工程/主要生产建筑/110kV站用配电装置室/一般土建"},{"_id":"{75A49C47-400D-4CD1-8B80-0F29E5ADDD6C}","nodeType":"项目划分","parentId":"{D59DD5FE-D445-4356-88A3-A17A7F73AD60}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.20.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811120200","路径":"建筑工程/主要生产工程/主要生产建筑/110kV站用配电装置室/采暖、通风及空调"},{"_id":"{9D1B33B5-63AC-458F-8B0D-AC32FFFB4959}","nodeType":"项目划分","parentId":"{D59DD5FE-D445-4356-88A3-A17A7F73AD60}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.20.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811120300","路径":"建筑工程/主要生产工程/主要生产建筑/110kV站用配电装置室/照明"},{"_id":"{39603FE1-349C-4EF2-B24D-73284E6F826F}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"66kV站用配电装置室","备注":"","序号":"1.21","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811121000","路径":"建筑工程/主要生产工程/主要生产建筑/66kV站用配电装置室"},{"_id":"{33D653E0-77CB-4135-8425-6575D10F0F04}","nodeType":"项目划分","parentId":"{39603FE1-349C-4EF2-B24D-73284E6F826F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.21.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811121100","路径":"建筑工程/主要生产工程/主要生产建筑/66kV站用配电装置室/一般土建"},{"_id":"{A272923C-EA99-4F5C-8986-CCAC60AB239B}","nodeType":"项目划分","parentId":"{39603FE1-349C-4EF2-B24D-73284E6F826F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.21.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811121200","路径":"建筑工程/主要生产工程/主要生产建筑/66kV站用配电装置室/采暖、通风及空调"},{"_id":"{EC5284AD-910C-42AE-9AF6-4A5DB4B2DD28}","nodeType":"项目划分","parentId":"{39603FE1-349C-4EF2-B24D-73284E6F826F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.21.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811121300","路径":"建筑工程/主要生产工程/主要生产建筑/66kV站用配电装置室/照明"},{"_id":"{B1D2B03A-4DFB-48B3-BB42-0203A68AE2A3}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"35kV站用配电装置室","备注":"","序号":"1.22","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811122000","路径":"建筑工程/主要生产工程/主要生产建筑/35kV站用配电装置室"},{"_id":"{6BA33F21-1EE8-4944-8650-57C475854D7F}","nodeType":"项目划分","parentId":"{B1D2B03A-4DFB-48B3-BB42-0203A68AE2A3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.22.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811122100","路径":"建筑工程/主要生产工程/主要生产建筑/35kV站用配电装置室/一般土建"},{"_id":"{D9F6732B-AFC8-49C0-8A2F-3FE1C059622E}","nodeType":"项目划分","parentId":"{B1D2B03A-4DFB-48B3-BB42-0203A68AE2A3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.22.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811122200","路径":"建筑工程/主要生产工程/主要生产建筑/35kV站用配电装置室/采暖、通风及空调"},{"_id":"{640D2EC9-0C2E-40DE-A5D6-C1BBBC0EA7FE}","nodeType":"项目划分","parentId":"{B1D2B03A-4DFB-48B3-BB42-0203A68AE2A3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.22.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811122300","路径":"建筑工程/主要生产工程/主要生产建筑/35kV站用配电装置室/照明"},{"_id":"{9954F1B7-4CE3-4966-97D1-C329627F828A}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"20kV站用配电装置室","备注":"","序号":"1.23","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811123000","路径":"建筑工程/主要生产工程/主要生产建筑/20kV站用配电装置室"},{"_id":"{36C2BA7D-8408-4A44-BD5E-5DB4AF20B230}","nodeType":"项目划分","parentId":"{9954F1B7-4CE3-4966-97D1-C329627F828A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.23.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811123100","路径":"建筑工程/主要生产工程/主要生产建筑/20kV站用配电装置室/一般土建"},{"_id":"{23173C6C-1BE7-484B-B273-6E3E90C19BBC}","nodeType":"项目划分","parentId":"{9954F1B7-4CE3-4966-97D1-C329627F828A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.23.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811123200","路径":"建筑工程/主要生产工程/主要生产建筑/20kV站用配电装置室/采暖、通风及空调"},{"_id":"{09B4AD9E-767F-4BCD-A63D-CD5A44BACCC5}","nodeType":"项目划分","parentId":"{9954F1B7-4CE3-4966-97D1-C329627F828A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.23.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811123300","路径":"建筑工程/主要生产工程/主要生产建筑/20kV站用配电装置室/照明"},{"_id":"{C7E3616D-08BF-4F67-8AA5-3889AA9B2509}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"10kV站用配电装置室","备注":"","序号":"1.24","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811124000","路径":"建筑工程/主要生产工程/主要生产建筑/10kV站用配电装置室"},{"_id":"{66DDCEA4-51DE-49FC-B52A-C52957CA0991}","nodeType":"项目划分","parentId":"{C7E3616D-08BF-4F67-8AA5-3889AA9B2509}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.24.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811124100","路径":"建筑工程/主要生产工程/主要生产建筑/10kV站用配电装置室/一般土建"},{"_id":"{25FBC6A4-8AB4-4EFF-B51D-ED00A71774C3}","nodeType":"项目划分","parentId":"{C7E3616D-08BF-4F67-8AA5-3889AA9B2509}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.24.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811124200","路径":"建筑工程/主要生产工程/主要生产建筑/10kV站用配电装置室/采暖、通风及空调"},{"_id":"{5D84699A-D0C5-4F32-8CFF-3D97A04FD04A}","nodeType":"项目划分","parentId":"{C7E3616D-08BF-4F67-8AA5-3889AA9B2509}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.24.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811124300","路径":"建筑工程/主要生产工程/主要生产建筑/10kV站用配电装置室/照明"},{"_id":"{D7E0CDD9-40D0-430E-BBF5-4C1B2C066BF4}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"1000kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.25","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811125000","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV可控高压电抗器晶闸管阀室"},{"_id":"{5D95A51C-8113-4605-98DD-E886F187D1EC}","nodeType":"项目划分","parentId":"{D7E0CDD9-40D0-430E-BBF5-4C1B2C066BF4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.25.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811125100","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{1A224C76-1408-4F9B-800C-89D88A1F85CC}","nodeType":"项目划分","parentId":"{D7E0CDD9-40D0-430E-BBF5-4C1B2C066BF4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.25.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811125200","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{E595FDBD-09B9-4D39-A586-988D28B5AC55}","nodeType":"项目划分","parentId":"{D7E0CDD9-40D0-430E-BBF5-4C1B2C066BF4}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.25.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811125300","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{B8E7BEBE-20A5-4C33-B286-D102DEC8CDCD}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"750kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.26","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811126000","路径":"建筑工程/主要生产工程/主要生产建筑/750kV可控高压电抗器晶闸管阀室"},{"_id":"{C025653A-9791-4127-A658-7FA123014249}","nodeType":"项目划分","parentId":"{B8E7BEBE-20A5-4C33-B286-D102DEC8CDCD}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.26.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811126100","路径":"建筑工程/主要生产工程/主要生产建筑/750kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{4ECA2657-449E-4D49-A249-EE9FAD121934}","nodeType":"项目划分","parentId":"{B8E7BEBE-20A5-4C33-B286-D102DEC8CDCD}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.26.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811126200","路径":"建筑工程/主要生产工程/主要生产建筑/750kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{3B073CD3-EBE7-4173-9A61-1815AFCB6135}","nodeType":"项目划分","parentId":"{B8E7BEBE-20A5-4C33-B286-D102DEC8CDCD}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.26.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811126300","路径":"建筑工程/主要生产工程/主要生产建筑/750kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{E12B73FA-03E4-4158-95DB-6229F618192E}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"660kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.27","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811127000","路径":"建筑工程/主要生产工程/主要生产建筑/660kV可控高压电抗器晶闸管阀室"},{"_id":"{F537A874-898D-47EC-9E1E-5375C597005D}","nodeType":"项目划分","parentId":"{E12B73FA-03E4-4158-95DB-6229F618192E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.27.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811127100","路径":"建筑工程/主要生产工程/主要生产建筑/660kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{CCE2608D-65D1-49D6-B69B-E7CB3DD0BC14}","nodeType":"项目划分","parentId":"{E12B73FA-03E4-4158-95DB-6229F618192E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.27.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811127200","路径":"建筑工程/主要生产工程/主要生产建筑/660kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{E039D659-EF53-4F2A-B901-3BD023FF2EB2}","nodeType":"项目划分","parentId":"{E12B73FA-03E4-4158-95DB-6229F618192E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.27.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811127300","路径":"建筑工程/主要生产工程/主要生产建筑/660kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{DC7C5E37-8E84-4C39-84C3-7174456E7851}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"500kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.28","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811128000","路径":"建筑工程/主要生产工程/主要生产建筑/500kV可控高压电抗器晶闸管阀室"},{"_id":"{EA4A521D-4594-4BCD-A911-460E8C0011F5}","nodeType":"项目划分","parentId":"{DC7C5E37-8E84-4C39-84C3-7174456E7851}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.28.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811128100","路径":"建筑工程/主要生产工程/主要生产建筑/500kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{C4FD5A76-C2AB-4727-92E7-0D5CEBE3F7FB}","nodeType":"项目划分","parentId":"{DC7C5E37-8E84-4C39-84C3-7174456E7851}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.28.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811128200","路径":"建筑工程/主要生产工程/主要生产建筑/500kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{A2F2627B-0787-45D8-8E86-FC6D608DAA9E}","nodeType":"项目划分","parentId":"{DC7C5E37-8E84-4C39-84C3-7174456E7851}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.28.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811128300","路径":"建筑工程/主要生产工程/主要生产建筑/500kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{4B141DED-4F30-4FBB-99E2-608F3BEF9509}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"330kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.29","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811129000","路径":"建筑工程/主要生产工程/主要生产建筑/330kV可控高压电抗器晶闸管阀室"},{"_id":"{27EDF958-5DFA-460E-8F33-6FFF2702619C}","nodeType":"项目划分","parentId":"{4B141DED-4F30-4FBB-99E2-608F3BEF9509}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.29.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811129100","路径":"建筑工程/主要生产工程/主要生产建筑/330kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{9BD75E7D-7614-4DAE-8ED3-05348B5B19D6}","nodeType":"项目划分","parentId":"{4B141DED-4F30-4FBB-99E2-608F3BEF9509}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.29.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811129200","路径":"建筑工程/主要生产工程/主要生产建筑/330kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{518349DE-29BA-4800-BED4-6E876F5A2234}","nodeType":"项目划分","parentId":"{4B141DED-4F30-4FBB-99E2-608F3BEF9509}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.29.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811129300","路径":"建筑工程/主要生产工程/主要生产建筑/330kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{0AA2CBC9-27C7-484F-8A0A-490EC78C69DD}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"220kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.30","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811130000","路径":"建筑工程/主要生产工程/主要生产建筑/220kV可控高压电抗器晶闸管阀室"},{"_id":"{74D3E94E-BD18-4654-8019-B7CBEBD1FEBA}","nodeType":"项目划分","parentId":"{0AA2CBC9-27C7-484F-8A0A-490EC78C69DD}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.30.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811130100","路径":"建筑工程/主要生产工程/主要生产建筑/220kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{C4104CCD-D29B-4F14-8259-F0828924CC3B}","nodeType":"项目划分","parentId":"{0AA2CBC9-27C7-484F-8A0A-490EC78C69DD}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.30.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811130200","路径":"建筑工程/主要生产工程/主要生产建筑/220kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{AD4014EF-E9AC-41FA-8B02-4583A68E7390}","nodeType":"项目划分","parentId":"{0AA2CBC9-27C7-484F-8A0A-490EC78C69DD}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.30.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811130300","路径":"建筑工程/主要生产工程/主要生产建筑/220kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{ECDC90F4-2C89-4E3C-972F-F1C0A9F282B8}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"110kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.31","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811131000","路径":"建筑工程/主要生产工程/主要生产建筑/110kV可控高压电抗器晶闸管阀室"},{"_id":"{212D01E5-EE4A-475A-B78D-02E07FCF951C}","nodeType":"项目划分","parentId":"{ECDC90F4-2C89-4E3C-972F-F1C0A9F282B8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.31.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811131100","路径":"建筑工程/主要生产工程/主要生产建筑/110kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{6062EB47-3579-4829-83B2-B93B6BC60A11}","nodeType":"项目划分","parentId":"{ECDC90F4-2C89-4E3C-972F-F1C0A9F282B8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.31.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811131200","路径":"建筑工程/主要生产工程/主要生产建筑/110kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{9D7A19C7-7786-4BB8-A8F2-B611F8A3DE46}","nodeType":"项目划分","parentId":"{ECDC90F4-2C89-4E3C-972F-F1C0A9F282B8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.31.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811131300","路径":"建筑工程/主要生产工程/主要生产建筑/110kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{24266493-EB9A-4295-9528-7D8A23D44177}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"66kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.32","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811132000","路径":"建筑工程/主要生产工程/主要生产建筑/66kV可控高压电抗器晶闸管阀室"},{"_id":"{631B98CD-A36B-4E31-993A-1DF5994E48E1}","nodeType":"项目划分","parentId":"{24266493-EB9A-4295-9528-7D8A23D44177}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.32.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811132100","路径":"建筑工程/主要生产工程/主要生产建筑/66kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{75E6C6AE-947B-4189-9EF1-47992B72F09B}","nodeType":"项目划分","parentId":"{24266493-EB9A-4295-9528-7D8A23D44177}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.32.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811132200","路径":"建筑工程/主要生产工程/主要生产建筑/66kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{ED20D147-E832-46A7-9719-46386703C045}","nodeType":"项目划分","parentId":"{24266493-EB9A-4295-9528-7D8A23D44177}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.32.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811132300","路径":"建筑工程/主要生产工程/主要生产建筑/66kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{ADC50397-4D58-4BDC-BD81-D7A671BBFDAE}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"35kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.33","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811133000","路径":"建筑工程/主要生产工程/主要生产建筑/35kV可控高压电抗器晶闸管阀室"},{"_id":"{0B7B67F9-17A9-4D5B-9547-2591E415554D}","nodeType":"项目划分","parentId":"{ADC50397-4D58-4BDC-BD81-D7A671BBFDAE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.33.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811133100","路径":"建筑工程/主要生产工程/主要生产建筑/35kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{BA3B4E67-2D56-48C2-977D-552E87235F16}","nodeType":"项目划分","parentId":"{ADC50397-4D58-4BDC-BD81-D7A671BBFDAE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.33.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811133200","路径":"建筑工程/主要生产工程/主要生产建筑/35kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{9A258810-D399-4F4B-9C38-CA7E90B4AB5F}","nodeType":"项目划分","parentId":"{ADC50397-4D58-4BDC-BD81-D7A671BBFDAE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.33.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811133300","路径":"建筑工程/主要生产工程/主要生产建筑/35kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{107FE645-4DC8-4371-99DC-01DCFA44B640}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"20kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.34","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811134000","路径":"建筑工程/主要生产工程/主要生产建筑/20kV可控高压电抗器晶闸管阀室"},{"_id":"{9949E80C-CCA5-4755-AF25-E1F021A038F2}","nodeType":"项目划分","parentId":"{107FE645-4DC8-4371-99DC-01DCFA44B640}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.34.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811134100","路径":"建筑工程/主要生产工程/主要生产建筑/20kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{BBF3B241-ABAC-4A9F-90AF-161CE119F64E}","nodeType":"项目划分","parentId":"{107FE645-4DC8-4371-99DC-01DCFA44B640}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.34.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811134200","路径":"建筑工程/主要生产工程/主要生产建筑/20kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{2E0A16CE-235B-409C-80D2-6122F416B003}","nodeType":"项目划分","parentId":"{107FE645-4DC8-4371-99DC-01DCFA44B640}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.34.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811134300","路径":"建筑工程/主要生产工程/主要生产建筑/20kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{5E6D245A-3B4C-4AB6-9930-F12A01C8CAFB}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"10kV可控高压电抗器晶闸管阀室","备注":"","序号":"1.35","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811135000","路径":"建筑工程/主要生产工程/主要生产建筑/10kV可控高压电抗器晶闸管阀室"},{"_id":"{B8F5AC4E-062E-4DD7-A679-110ED0D66BC7}","nodeType":"项目划分","parentId":"{5E6D245A-3B4C-4AB6-9930-F12A01C8CAFB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.35.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811135100","路径":"建筑工程/主要生产工程/主要生产建筑/10kV可控高压电抗器晶闸管阀室/一般土建"},{"_id":"{0DE7CE7D-D399-4DDC-B179-638746E6E547}","nodeType":"项目划分","parentId":"{5E6D245A-3B4C-4AB6-9930-F12A01C8CAFB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.35.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811135200","路径":"建筑工程/主要生产工程/主要生产建筑/10kV可控高压电抗器晶闸管阀室/采暖、通风及空调"},{"_id":"{1EC2A892-C722-4A68-A42B-88A2EE66B959}","nodeType":"项目划分","parentId":"{5E6D245A-3B4C-4AB6-9930-F12A01C8CAFB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.35.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811135300","路径":"建筑工程/主要生产工程/主要生产建筑/10kV可控高压电抗器晶闸管阀室/照明"},{"_id":"{3E58513D-ED8F-489B-BA6F-AD35F32B238F}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"1000kV固定串联补偿装置控制室","备注":"","序号":"1.36","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811136000","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV固定串联补偿装置控制室"},{"_id":"{D9D5AC8C-D3B9-4DD8-A850-15EFBFED9607}","nodeType":"项目划分","parentId":"{3E58513D-ED8F-489B-BA6F-AD35F32B238F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.36.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811136100","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV固定串联补偿装置控制室/一般土建"},{"_id":"{E4EBF77A-0C0D-4F66-A9F9-672671E5242A}","nodeType":"项目划分","parentId":"{3E58513D-ED8F-489B-BA6F-AD35F32B238F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.36.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811136200","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{D5A7FFB5-2EA9-4927-8C8B-8A278C56C1EC}","nodeType":"项目划分","parentId":"{3E58513D-ED8F-489B-BA6F-AD35F32B238F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.36.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811136300","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV固定串联补偿装置控制室/照明"},{"_id":"{E430CB1B-2381-4DC5-BFA0-6FB5E9E6D45B}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"750kV固定串联补偿装置控制室","备注":"","序号":"1.37","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811137000","路径":"建筑工程/主要生产工程/主要生产建筑/750kV固定串联补偿装置控制室"},{"_id":"{B5A5C551-0F52-41F2-958E-6B8F80537853}","nodeType":"项目划分","parentId":"{E430CB1B-2381-4DC5-BFA0-6FB5E9E6D45B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.37.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811137100","路径":"建筑工程/主要生产工程/主要生产建筑/750kV固定串联补偿装置控制室/一般土建"},{"_id":"{D93FF4BA-F53F-4CD6-A12B-4370893557BB}","nodeType":"项目划分","parentId":"{E430CB1B-2381-4DC5-BFA0-6FB5E9E6D45B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.37.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811137200","路径":"建筑工程/主要生产工程/主要生产建筑/750kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{975EC737-999C-49C5-92DC-78CFB5EE050A}","nodeType":"项目划分","parentId":"{E430CB1B-2381-4DC5-BFA0-6FB5E9E6D45B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.37.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811137300","路径":"建筑工程/主要生产工程/主要生产建筑/750kV固定串联补偿装置控制室/照明"},{"_id":"{0476FFC9-C9C0-4FA3-B7B2-6405A2C171DB}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"660kV固定串联补偿装置控制室","备注":"","序号":"1.38","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811138000","路径":"建筑工程/主要生产工程/主要生产建筑/660kV固定串联补偿装置控制室"},{"_id":"{F7EDF443-3DC4-4C8D-ACAD-D6A0C88D3884}","nodeType":"项目划分","parentId":"{0476FFC9-C9C0-4FA3-B7B2-6405A2C171DB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.38.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811138100","路径":"建筑工程/主要生产工程/主要生产建筑/660kV固定串联补偿装置控制室/一般土建"},{"_id":"{AB2F87E1-17B1-4D80-922A-6B153C18AAA3}","nodeType":"项目划分","parentId":"{0476FFC9-C9C0-4FA3-B7B2-6405A2C171DB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.38.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811138200","路径":"建筑工程/主要生产工程/主要生产建筑/660kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{6B766B69-8C6F-47A8-B116-DD00B334D229}","nodeType":"项目划分","parentId":"{0476FFC9-C9C0-4FA3-B7B2-6405A2C171DB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.38.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811138300","路径":"建筑工程/主要生产工程/主要生产建筑/660kV固定串联补偿装置控制室/照明"},{"_id":"{B18C22E4-05F8-4B94-AD8E-C085CFE5DF4F}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"500kV固定串联补偿装置控制室","备注":"","序号":"1.39","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811139000","路径":"建筑工程/主要生产工程/主要生产建筑/500kV固定串联补偿装置控制室"},{"_id":"{32DB5D3E-8281-4379-889A-852AAA8680F5}","nodeType":"项目划分","parentId":"{B18C22E4-05F8-4B94-AD8E-C085CFE5DF4F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.39.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811139100","路径":"建筑工程/主要生产工程/主要生产建筑/500kV固定串联补偿装置控制室/一般土建"},{"_id":"{BE33E45C-CB18-490E-ABE6-8422AFD9F955}","nodeType":"项目划分","parentId":"{B18C22E4-05F8-4B94-AD8E-C085CFE5DF4F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.39.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811139200","路径":"建筑工程/主要生产工程/主要生产建筑/500kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{AD4BEA11-7909-4446-8C77-94BF507CC82A}","nodeType":"项目划分","parentId":"{B18C22E4-05F8-4B94-AD8E-C085CFE5DF4F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.39.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811139300","路径":"建筑工程/主要生产工程/主要生产建筑/500kV固定串联补偿装置控制室/照明"},{"_id":"{EF914EE7-B449-4720-A3F2-BAE8D1E16695}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"330kV固定串联补偿装置控制室","备注":"","序号":"1.40","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811140000","路径":"建筑工程/主要生产工程/主要生产建筑/330kV固定串联补偿装置控制室"},{"_id":"{9743CA77-68CC-441B-BD27-A828B0CA5991}","nodeType":"项目划分","parentId":"{EF914EE7-B449-4720-A3F2-BAE8D1E16695}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.40.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811140100","路径":"建筑工程/主要生产工程/主要生产建筑/330kV固定串联补偿装置控制室/一般土建"},{"_id":"{C2AA6F64-ABD5-4FDD-AE94-745DD59BBBD0}","nodeType":"项目划分","parentId":"{EF914EE7-B449-4720-A3F2-BAE8D1E16695}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.40.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811140200","路径":"建筑工程/主要生产工程/主要生产建筑/330kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{573E2A6F-B01D-4D2E-B3C7-2E47D8B52384}","nodeType":"项目划分","parentId":"{EF914EE7-B449-4720-A3F2-BAE8D1E16695}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.40.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811140300","路径":"建筑工程/主要生产工程/主要生产建筑/330kV固定串联补偿装置控制室/照明"},{"_id":"{D2E03B18-B0B4-4984-A1B9-73C96903796F}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"220kV固定串联补偿装置控制室","备注":"","序号":"1.41","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811141000","路径":"建筑工程/主要生产工程/主要生产建筑/220kV固定串联补偿装置控制室"},{"_id":"{C5D0B9EB-B568-4D25-9D4D-BD0E4A7C250B}","nodeType":"项目划分","parentId":"{D2E03B18-B0B4-4984-A1B9-73C96903796F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.41.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811141100","路径":"建筑工程/主要生产工程/主要生产建筑/220kV固定串联补偿装置控制室/一般土建"},{"_id":"{E944740B-3E11-41B4-85A9-FC495A4A6A97}","nodeType":"项目划分","parentId":"{D2E03B18-B0B4-4984-A1B9-73C96903796F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.41.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811141200","路径":"建筑工程/主要生产工程/主要生产建筑/220kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{0FD7B143-B9AE-4BF4-8C7A-6CE7A3868303}","nodeType":"项目划分","parentId":"{D2E03B18-B0B4-4984-A1B9-73C96903796F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.41.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811141300","路径":"建筑工程/主要生产工程/主要生产建筑/220kV固定串联补偿装置控制室/照明"},{"_id":"{870A79AD-2D6A-4037-A3D4-B2ACB7BDC399}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"110kV固定串联补偿装置控制室","备注":"","序号":"1.42","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811142000","路径":"建筑工程/主要生产工程/主要生产建筑/110kV固定串联补偿装置控制室"},{"_id":"{F0FC56A5-F2BC-48A5-8345-D4E212444AB9}","nodeType":"项目划分","parentId":"{870A79AD-2D6A-4037-A3D4-B2ACB7BDC399}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.42.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811142100","路径":"建筑工程/主要生产工程/主要生产建筑/110kV固定串联补偿装置控制室/一般土建"},{"_id":"{DC864860-CD9A-4A99-886B-39269DDD3EFF}","nodeType":"项目划分","parentId":"{870A79AD-2D6A-4037-A3D4-B2ACB7BDC399}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.42.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811142200","路径":"建筑工程/主要生产工程/主要生产建筑/110kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{BCE68D20-9D8F-4763-B700-E1A6BF57932A}","nodeType":"项目划分","parentId":"{870A79AD-2D6A-4037-A3D4-B2ACB7BDC399}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.42.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811142300","路径":"建筑工程/主要生产工程/主要生产建筑/110kV固定串联补偿装置控制室/照明"},{"_id":"{EF15C016-35F1-4639-B3BB-ED434242AD6A}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"66kV固定串联补偿装置控制室","备注":"","序号":"1.43","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811143000","路径":"建筑工程/主要生产工程/主要生产建筑/66kV固定串联补偿装置控制室"},{"_id":"{70754935-6135-4B14-B426-0214876CE8AF}","nodeType":"项目划分","parentId":"{EF15C016-35F1-4639-B3BB-ED434242AD6A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.43.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811143100","路径":"建筑工程/主要生产工程/主要生产建筑/66kV固定串联补偿装置控制室/一般土建"},{"_id":"{FE84F094-31D2-4AEF-B0A5-95DDDDC53A80}","nodeType":"项目划分","parentId":"{EF15C016-35F1-4639-B3BB-ED434242AD6A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.43.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811143200","路径":"建筑工程/主要生产工程/主要生产建筑/66kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{30A7E84A-7202-4926-8E87-105123DBEF35}","nodeType":"项目划分","parentId":"{EF15C016-35F1-4639-B3BB-ED434242AD6A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.43.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811143300","路径":"建筑工程/主要生产工程/主要生产建筑/66kV固定串联补偿装置控制室/照明"},{"_id":"{7A60B62C-964A-40BF-88AD-68D1C38888C8}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"35kV固定串联补偿装置控制室","备注":"","序号":"1.44","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811144000","路径":"建筑工程/主要生产工程/主要生产建筑/35kV固定串联补偿装置控制室"},{"_id":"{71F67343-F81E-4D1B-914F-F82A9858C3A9}","nodeType":"项目划分","parentId":"{7A60B62C-964A-40BF-88AD-68D1C38888C8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.44.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811144100","路径":"建筑工程/主要生产工程/主要生产建筑/35kV固定串联补偿装置控制室/一般土建"},{"_id":"{5F2FBF9C-A388-429D-9192-C6FDA9D56D3C}","nodeType":"项目划分","parentId":"{7A60B62C-964A-40BF-88AD-68D1C38888C8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.44.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811144200","路径":"建筑工程/主要生产工程/主要生产建筑/35kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{C08FEF7A-E989-492C-8A9B-22E04FCAAA0B}","nodeType":"项目划分","parentId":"{7A60B62C-964A-40BF-88AD-68D1C38888C8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.44.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811144300","路径":"建筑工程/主要生产工程/主要生产建筑/35kV固定串联补偿装置控制室/照明"},{"_id":"{1F11501A-9AEA-4616-919D-B1C9A9C23B33}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"20kV固定串联补偿装置控制室","备注":"","序号":"1.45","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811145000","路径":"建筑工程/主要生产工程/主要生产建筑/20kV固定串联补偿装置控制室"},{"_id":"{BA2A5F0A-3302-4DD8-B90F-0EA9C0F95FA3}","nodeType":"项目划分","parentId":"{1F11501A-9AEA-4616-919D-B1C9A9C23B33}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.45.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811145100","路径":"建筑工程/主要生产工程/主要生产建筑/20kV固定串联补偿装置控制室/一般土建"},{"_id":"{F2A7269B-917A-4099-A5EB-A3332745FBB3}","nodeType":"项目划分","parentId":"{1F11501A-9AEA-4616-919D-B1C9A9C23B33}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.45.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811145200","路径":"建筑工程/主要生产工程/主要生产建筑/20kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{CEF57F7A-4990-484A-8B1D-33D9B0F83293}","nodeType":"项目划分","parentId":"{1F11501A-9AEA-4616-919D-B1C9A9C23B33}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.45.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811145300","路径":"建筑工程/主要生产工程/主要生产建筑/20kV固定串联补偿装置控制室/照明"},{"_id":"{DA47CFE6-07E3-47D3-A206-EF9E70B8F549}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"10kV固定串联补偿装置控制室","备注":"","序号":"1.46","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811146000","路径":"建筑工程/主要生产工程/主要生产建筑/10kV固定串联补偿装置控制室"},{"_id":"{159DFE7E-E36C-4EDE-B164-0055B91B710F}","nodeType":"项目划分","parentId":"{DA47CFE6-07E3-47D3-A206-EF9E70B8F549}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.46.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811146100","路径":"建筑工程/主要生产工程/主要生产建筑/10kV固定串联补偿装置控制室/一般土建"},{"_id":"{98BE31FA-54B5-43B4-BA9A-CC683D026D91}","nodeType":"项目划分","parentId":"{DA47CFE6-07E3-47D3-A206-EF9E70B8F549}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.46.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811146200","路径":"建筑工程/主要生产工程/主要生产建筑/10kV固定串联补偿装置控制室/采暖、通风及空调"},{"_id":"{83F240DA-6680-4873-88A0-D7B3F0494FED}","nodeType":"项目划分","parentId":"{DA47CFE6-07E3-47D3-A206-EF9E70B8F549}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.46.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811146300","路径":"建筑工程/主要生产工程/主要生产建筑/10kV固定串联补偿装置控制室/照明"},{"_id":"{F8B98F89-14D1-4153-BBD6-1490FE3DF547}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"可控串联补偿装置控制室","备注":"","序号":"1.47","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811147000","路径":"建筑工程/主要生产工程/主要生产建筑/可控串联补偿装置控制室"},{"_id":"{045CD33D-8390-4A1F-A9D6-504BD58CC107}","nodeType":"项目划分","parentId":"{F8B98F89-14D1-4153-BBD6-1490FE3DF547}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.47.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811147100","路径":"建筑工程/主要生产工程/主要生产建筑/可控串联补偿装置控制室/一般土建"},{"_id":"{2F7CC170-1966-48F6-860F-6B448F47C1BF}","nodeType":"项目划分","parentId":"{F8B98F89-14D1-4153-BBD6-1490FE3DF547}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.47.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811147200","路径":"建筑工程/主要生产工程/主要生产建筑/可控串联补偿装置控制室/采暖、通风及空调"},{"_id":"{A2CE5B24-E382-4A86-94B9-9531D7D4DA06}","nodeType":"项目划分","parentId":"{F8B98F89-14D1-4153-BBD6-1490FE3DF547}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.47.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811147300","路径":"建筑工程/主要生产工程/主要生产建筑/可控串联补偿装置控制室/照明"},{"_id":"{074A2B2C-9D49-4861-91B4-8158368C718C}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"1000kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.48","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811148000","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV静止无功补偿装置晶闸管阀室"},{"_id":"{7235617A-C62A-4A02-B506-1BFC352E66BC}","nodeType":"项目划分","parentId":"{074A2B2C-9D49-4861-91B4-8158368C718C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.48.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811148100","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{807D34C9-D82F-4685-9E67-4BD1157F5917}","nodeType":"项目划分","parentId":"{074A2B2C-9D49-4861-91B4-8158368C718C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.48.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811148200","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{AE2F5E80-2D8B-4C2B-9437-1FFE64CC9C23}","nodeType":"项目划分","parentId":"{074A2B2C-9D49-4861-91B4-8158368C718C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.48.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811148300","路径":"建筑工程/主要生产工程/主要生产建筑/1000kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{8D1FC899-BC6C-4165-9FEF-C78A4735DD89}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"750kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.49","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811149000","路径":"建筑工程/主要生产工程/主要生产建筑/750kV静止无功补偿装置晶闸管阀室"},{"_id":"{5E28AE3F-07B1-4024-89A6-BFD4AE7D028B}","nodeType":"项目划分","parentId":"{8D1FC899-BC6C-4165-9FEF-C78A4735DD89}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.49.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811149100","路径":"建筑工程/主要生产工程/主要生产建筑/750kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{B7A0D1E1-BC52-4AE0-A6CB-43D41BC65CB7}","nodeType":"项目划分","parentId":"{8D1FC899-BC6C-4165-9FEF-C78A4735DD89}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.49.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811149200","路径":"建筑工程/主要生产工程/主要生产建筑/750kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{3D1F746B-56E7-42EE-8A97-28DC18B522EC}","nodeType":"项目划分","parentId":"{8D1FC899-BC6C-4165-9FEF-C78A4735DD89}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.49.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811149300","路径":"建筑工程/主要生产工程/主要生产建筑/750kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{5F77DB6A-A789-4C87-A25A-51E88BD6E5CA}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"660kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.50","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811150000","路径":"建筑工程/主要生产工程/主要生产建筑/660kV静止无功补偿装置晶闸管阀室"},{"_id":"{7AC9DCAF-1212-456B-9A38-F891BE51DEA4}","nodeType":"项目划分","parentId":"{5F77DB6A-A789-4C87-A25A-51E88BD6E5CA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.50.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811150100","路径":"建筑工程/主要生产工程/主要生产建筑/660kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{D0E5DAE4-45B6-4906-AB6A-B7AE0AF6993A}","nodeType":"项目划分","parentId":"{5F77DB6A-A789-4C87-A25A-51E88BD6E5CA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.50.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811150200","路径":"建筑工程/主要生产工程/主要生产建筑/660kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{B843A0F0-33EE-4CDE-B61F-A8113C033548}","nodeType":"项目划分","parentId":"{5F77DB6A-A789-4C87-A25A-51E88BD6E5CA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.50.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811150300","路径":"建筑工程/主要生产工程/主要生产建筑/660kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{C6A295D0-4271-4691-AA40-69B77F6689E6}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"500kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.51","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811151000","路径":"建筑工程/主要生产工程/主要生产建筑/500kV静止无功补偿装置晶闸管阀室"},{"_id":"{B12BCC8F-DA42-428B-9B6D-5B596327CFD6}","nodeType":"项目划分","parentId":"{C6A295D0-4271-4691-AA40-69B77F6689E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.51.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811151100","路径":"建筑工程/主要生产工程/主要生产建筑/500kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{DD8495E1-46D9-4E17-929F-EDE270A247AC}","nodeType":"项目划分","parentId":"{C6A295D0-4271-4691-AA40-69B77F6689E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.51.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811151200","路径":"建筑工程/主要生产工程/主要生产建筑/500kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{3F2F4ADB-92EE-4928-8DD3-D01715C09524}","nodeType":"项目划分","parentId":"{C6A295D0-4271-4691-AA40-69B77F6689E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.51.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811151300","路径":"建筑工程/主要生产工程/主要生产建筑/500kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{81DC5A32-9F17-4F84-B5F6-9B5AD2DC564F}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"330kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.52","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811152000","路径":"建筑工程/主要生产工程/主要生产建筑/330kV静止无功补偿装置晶闸管阀室"},{"_id":"{E2E76169-6F92-4B52-BEFF-C9EC093DAC7F}","nodeType":"项目划分","parentId":"{81DC5A32-9F17-4F84-B5F6-9B5AD2DC564F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.52.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811152100","路径":"建筑工程/主要生产工程/主要生产建筑/330kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{A786FBDF-0546-4ABB-BD29-36390040ECBB}","nodeType":"项目划分","parentId":"{81DC5A32-9F17-4F84-B5F6-9B5AD2DC564F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.52.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811152200","路径":"建筑工程/主要生产工程/主要生产建筑/330kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{0CCC1DA3-F314-48C6-88BE-147197CF084A}","nodeType":"项目划分","parentId":"{81DC5A32-9F17-4F84-B5F6-9B5AD2DC564F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.52.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811152300","路径":"建筑工程/主要生产工程/主要生产建筑/330kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{7995CDCF-6349-490D-A3B7-3A4C64303C6A}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"220kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.53","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811153000","路径":"建筑工程/主要生产工程/主要生产建筑/220kV静止无功补偿装置晶闸管阀室"},{"_id":"{090B0FA3-0948-4D01-8D7F-687CDFC3A120}","nodeType":"项目划分","parentId":"{7995CDCF-6349-490D-A3B7-3A4C64303C6A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.53.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811153100","路径":"建筑工程/主要生产工程/主要生产建筑/220kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{8829DFE0-487F-45AF-B8E4-309006454F87}","nodeType":"项目划分","parentId":"{7995CDCF-6349-490D-A3B7-3A4C64303C6A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.53.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811153200","路径":"建筑工程/主要生产工程/主要生产建筑/220kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{13E4A0CE-17D3-47D0-A58F-8DDA914B8FB5}","nodeType":"项目划分","parentId":"{7995CDCF-6349-490D-A3B7-3A4C64303C6A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.53.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811153300","路径":"建筑工程/主要生产工程/主要生产建筑/220kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{277FB425-44E7-4691-8E0C-AADE27AA31CE}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"110kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.54","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811154000","路径":"建筑工程/主要生产工程/主要生产建筑/110kV静止无功补偿装置晶闸管阀室"},{"_id":"{56214B3F-2802-4339-90D8-955E880BD65E}","nodeType":"项目划分","parentId":"{277FB425-44E7-4691-8E0C-AADE27AA31CE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.54.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811154100","路径":"建筑工程/主要生产工程/主要生产建筑/110kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{83DC26EC-ED3A-4741-B980-E9D29719A9AC}","nodeType":"项目划分","parentId":"{277FB425-44E7-4691-8E0C-AADE27AA31CE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.54.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811154200","路径":"建筑工程/主要生产工程/主要生产建筑/110kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{E35FAA89-C061-4B3B-9ABC-3467301ED7CE}","nodeType":"项目划分","parentId":"{277FB425-44E7-4691-8E0C-AADE27AA31CE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.54.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811154300","路径":"建筑工程/主要生产工程/主要生产建筑/110kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{ADC19A43-9475-4521-AD60-2FAE34C8CCE8}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"66kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.55","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811155000","路径":"建筑工程/主要生产工程/主要生产建筑/66kV静止无功补偿装置晶闸管阀室"},{"_id":"{B3321A43-DC26-4B18-9BA1-674988ABF1F9}","nodeType":"项目划分","parentId":"{ADC19A43-9475-4521-AD60-2FAE34C8CCE8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.55.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811155100","路径":"建筑工程/主要生产工程/主要生产建筑/66kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{C94C7B18-53CF-49FC-AE53-F5C44C0CDF08}","nodeType":"项目划分","parentId":"{ADC19A43-9475-4521-AD60-2FAE34C8CCE8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.55.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811155200","路径":"建筑工程/主要生产工程/主要生产建筑/66kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{E39B5D00-C705-4230-8788-9AF03DF392BE}","nodeType":"项目划分","parentId":"{ADC19A43-9475-4521-AD60-2FAE34C8CCE8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.55.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811155300","路径":"建筑工程/主要生产工程/主要生产建筑/66kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{216D168C-E87C-4801-A04A-7A18C65A3D5F}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"35kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.56","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811156000","路径":"建筑工程/主要生产工程/主要生产建筑/35kV静止无功补偿装置晶闸管阀室"},{"_id":"{693A5C52-7DA2-44E7-959C-64719CA11F0B}","nodeType":"项目划分","parentId":"{216D168C-E87C-4801-A04A-7A18C65A3D5F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.56.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811156100","路径":"建筑工程/主要生产工程/主要生产建筑/35kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{9E2A6DDF-1677-491F-B3D3-DC18B6FD22FC}","nodeType":"项目划分","parentId":"{216D168C-E87C-4801-A04A-7A18C65A3D5F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.56.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811156200","路径":"建筑工程/主要生产工程/主要生产建筑/35kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{B57D5218-328A-476E-BD73-DB4B8AAFF72D}","nodeType":"项目划分","parentId":"{216D168C-E87C-4801-A04A-7A18C65A3D5F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.56.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811156300","路径":"建筑工程/主要生产工程/主要生产建筑/35kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{9428F857-E4F0-4820-A043-5B836E02FAF3}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"20kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.57","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811157000","路径":"建筑工程/主要生产工程/主要生产建筑/20kV静止无功补偿装置晶闸管阀室"},{"_id":"{C0D4CA3A-80D1-468B-BB4A-2D9DB78F20D4}","nodeType":"项目划分","parentId":"{9428F857-E4F0-4820-A043-5B836E02FAF3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.57.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811157100","路径":"建筑工程/主要生产工程/主要生产建筑/20kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{F22701E8-87A9-4D5D-AAE6-7FE611B63BBC}","nodeType":"项目划分","parentId":"{9428F857-E4F0-4820-A043-5B836E02FAF3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.57.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811157200","路径":"建筑工程/主要生产工程/主要生产建筑/20kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{63EDED05-3B00-4FA8-96CD-D4C39BF2B3B4}","nodeType":"项目划分","parentId":"{9428F857-E4F0-4820-A043-5B836E02FAF3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.57.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811157300","路径":"建筑工程/主要生产工程/主要生产建筑/20kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{CF76A87A-ED61-445A-9DD6-9C5B08778EA1}","nodeType":"项目划分","parentId":"{5A29FF14-403D-4940-B436-D62A907FD440}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"","合价":"0","名称":"10kV静止无功补偿装置晶闸管阀室","备注":"","序号":"1.58","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811158000","路径":"建筑工程/主要生产工程/主要生产建筑/10kV静止无功补偿装置晶闸管阀室"},{"_id":"{75E1FCFE-52A1-4AA3-8BB1-45DD95DE8630}","nodeType":"项目划分","parentId":"{CF76A87A-ED61-445A-9DD6-9C5B08778EA1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.58.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811158100","路径":"建筑工程/主要生产工程/主要生产建筑/10kV静止无功补偿装置晶闸管阀室/一般土建"},{"_id":"{97AB774C-A060-4BC0-8F26-6B29AC019D07}","nodeType":"项目划分","parentId":"{CF76A87A-ED61-445A-9DD6-9C5B08778EA1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.58.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811158200","路径":"建筑工程/主要生产工程/主要生产建筑/10kV静止无功补偿装置晶闸管阀室/采暖、通风及空调"},{"_id":"{2B9A12E0-818C-448B-9328-C60863D248B1}","nodeType":"项目划分","parentId":"{CF76A87A-ED61-445A-9DD6-9C5B08778EA1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.58.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811158300","路径":"建筑工程/主要生产工程/主要生产建筑/10kV静止无功补偿装置晶闸管阀室/照明"},{"_id":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","nodeType":"项目划分","parentId":"{CECBFEE2-0081-45F6-8BDC-08CF271B43A1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"配电装置建筑","备注":"","序号":"2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811200000","路径":"建筑工程/主要生产工程/配电装置建筑"},{"_id":"{BD435DC3-133C-4859-B75D-7369E7830A2F}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/台","取费表":"","合价":"0","名称":"主变压器系统","备注":"","序号":"2.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811201000","路径":"建筑工程/主要生产工程/配电装置建筑/主变压器系统"},{"_id":"{38F073F0-99D5-455B-9DF0-BE7B4C5469BB}","nodeType":"项目划分","parentId":"{BD435DC3-133C-4859-B75D-7369E7830A2F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.1.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811201100","路径":"建筑工程/主要生产工程/配电装置建筑/主变压器系统/构支架及基础"},{"_id":"{6FE19639-BA76-425F-8556-608EF6BF5EAE}","nodeType":"项目划分","parentId":"{BD435DC3-133C-4859-B75D-7369E7830A2F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"主变压器设备基础","备注":"","序号":"2.1.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811201200","路径":"建筑工程/主要生产工程/配电装置建筑/主变压器系统/主变压器设备基础"},{"_id":"{94FA3DFB-7F4B-44D8-B5B7-54B4DF0246CC}","nodeType":"项目划分","parentId":"{BD435DC3-133C-4859-B75D-7369E7830A2F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"主变压器油坑及卵石","备注":"","序号":"2.1.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811201300","路径":"建筑工程/主要生产工程/配电装置建筑/主变压器系统/主变压器油坑及卵石"},{"_id":"{2BC031C3-BDF7-43F9-8037-8BEC12DD9BE4}","nodeType":"项目划分","parentId":"{BD435DC3-133C-4859-B75D-7369E7830A2F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.1.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811201400","路径":"建筑工程/主要生产工程/配电装置建筑/主变压器系统/防火墙"},{"_id":"{4FA40D80-4FCB-4CF8-8936-6986F9F29670}","nodeType":"项目划分","parentId":"{BD435DC3-133C-4859-B75D-7369E7830A2F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.1.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811201500","路径":"建筑工程/主要生产工程/配电装置建筑/主变压器系统/xxm³事故油池"},{"_id":"{E0E41EC6-8592-40CF-B8D9-6C64BA215747}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"1000kV构支架及设备基础","备注":"","序号":"2.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811202000","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV构支架及设备基础"},{"_id":"{06E56CF0-0D3F-4674-AD15-830DC7845455}","nodeType":"项目划分","parentId":"{E0E41EC6-8592-40CF-B8D9-6C64BA215747}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.2.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811202100","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV构支架及设备基础/构架及基础"},{"_id":"{7EA62CD6-9CE9-4024-BEB0-FCEB82D1C146}","nodeType":"项目划分","parentId":"{E0E41EC6-8592-40CF-B8D9-6C64BA215747}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.2.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811202200","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV构支架及设备基础/支架及基础"},{"_id":"{52F70A7D-CDF8-452C-B86E-9E2B56B30A99}","nodeType":"项目划分","parentId":"{E0E41EC6-8592-40CF-B8D9-6C64BA215747}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.2.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811202300","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV构支架及设备基础/设备基础"},{"_id":"{846AC6DC-EC3B-49E1-B093-09AB9D46047C}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"750kV构支架及设备基础","备注":"","序号":"2.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811203000","路径":"建筑工程/主要生产工程/配电装置建筑/750kV构支架及设备基础"},{"_id":"{2644642B-656A-44F1-A597-4A18D52088C0}","nodeType":"项目划分","parentId":"{846AC6DC-EC3B-49E1-B093-09AB9D46047C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811203100","路径":"建筑工程/主要生产工程/配电装置建筑/750kV构支架及设备基础/构架及基础"},{"_id":"{7E44431F-D779-4FE0-8979-A1164CF95DE3}","nodeType":"项目划分","parentId":"{846AC6DC-EC3B-49E1-B093-09AB9D46047C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811203200","路径":"建筑工程/主要生产工程/配电装置建筑/750kV构支架及设备基础/支架及基础"},{"_id":"{3754CE2D-95EC-4179-BB5B-7F767FB3F00C}","nodeType":"项目划分","parentId":"{846AC6DC-EC3B-49E1-B093-09AB9D46047C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811203300","路径":"建筑工程/主要生产工程/配电装置建筑/750kV构支架及设备基础/设备基础"},{"_id":"{83D2FD3E-38EB-4D0E-8B03-9DAB1B9F4D2B}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"660kV构支架及设备基础","备注":"","序号":"2.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811204000","路径":"建筑工程/主要生产工程/配电装置建筑/660kV构支架及设备基础"},{"_id":"{EADB54EC-3B00-4980-84DB-0572BFD4EFB1}","nodeType":"项目划分","parentId":"{83D2FD3E-38EB-4D0E-8B03-9DAB1B9F4D2B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.4.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811204100","路径":"建筑工程/主要生产工程/配电装置建筑/660kV构支架及设备基础/构架及基础"},{"_id":"{77AF7F55-9222-4411-B84F-4CBD60022816}","nodeType":"项目划分","parentId":"{83D2FD3E-38EB-4D0E-8B03-9DAB1B9F4D2B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.4.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811204200","路径":"建筑工程/主要生产工程/配电装置建筑/660kV构支架及设备基础/支架及基础"},{"_id":"{F2D64EB5-9C4B-43B7-8F13-363C394F2185}","nodeType":"项目划分","parentId":"{83D2FD3E-38EB-4D0E-8B03-9DAB1B9F4D2B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.4.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811204300","路径":"建筑工程/主要生产工程/配电装置建筑/660kV构支架及设备基础/设备基础"},{"_id":"{75E156E5-0C93-48A9-BDDA-D75C6DC93CD7}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"500kV构支架及设备基础","备注":"","序号":"2.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811205000","路径":"建筑工程/主要生产工程/配电装置建筑/500kV构支架及设备基础"},{"_id":"{76088B98-F8EE-42F6-AC36-65A9AB67D2CF}","nodeType":"项目划分","parentId":"{75E156E5-0C93-48A9-BDDA-D75C6DC93CD7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.5.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811205100","路径":"建筑工程/主要生产工程/配电装置建筑/500kV构支架及设备基础/构架及基础"},{"_id":"{1C5930C6-E18A-48E1-9B1B-9719EB852137}","nodeType":"项目划分","parentId":"{75E156E5-0C93-48A9-BDDA-D75C6DC93CD7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.5.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811205200","路径":"建筑工程/主要生产工程/配电装置建筑/500kV构支架及设备基础/支架及基础"},{"_id":"{9C134025-BEF1-4A63-979E-4DC333A0FCAD}","nodeType":"项目划分","parentId":"{75E156E5-0C93-48A9-BDDA-D75C6DC93CD7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.5.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811205300","路径":"建筑工程/主要生产工程/配电装置建筑/500kV构支架及设备基础/设备基础"},{"_id":"{AA9FB0BD-4F1B-4FC3-831D-BE43FB1B601B}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"330kV构支架及设备基础","备注":"","序号":"2.6","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811206000","路径":"建筑工程/主要生产工程/配电装置建筑/330kV构支架及设备基础"},{"_id":"{4EC4F5BF-5F7E-4BFF-9DFF-910CD8442126}","nodeType":"项目划分","parentId":"{AA9FB0BD-4F1B-4FC3-831D-BE43FB1B601B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.6.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811206100","路径":"建筑工程/主要生产工程/配电装置建筑/330kV构支架及设备基础/构架及基础"},{"_id":"{E7A4E1FB-C57F-4BF5-AD67-68E97E933382}","nodeType":"项目划分","parentId":"{AA9FB0BD-4F1B-4FC3-831D-BE43FB1B601B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.6.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811206200","路径":"建筑工程/主要生产工程/配电装置建筑/330kV构支架及设备基础/支架及基础"},{"_id":"{84F4A7F4-7794-40C4-9DE9-4E9F81AC36CC}","nodeType":"项目划分","parentId":"{AA9FB0BD-4F1B-4FC3-831D-BE43FB1B601B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.6.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811206300","路径":"建筑工程/主要生产工程/配电装置建筑/330kV构支架及设备基础/设备基础"},{"_id":"{A51A777A-ED22-48BC-B7A2-311FD782EE1E}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"220kV构支架及设备基础","备注":"","序号":"2.7","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811207000","路径":"建筑工程/主要生产工程/配电装置建筑/220kV构支架及设备基础"},{"_id":"{53151130-FDE8-4009-8797-58C470A2C7FC}","nodeType":"项目划分","parentId":"{A51A777A-ED22-48BC-B7A2-311FD782EE1E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.7.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811207100","路径":"建筑工程/主要生产工程/配电装置建筑/220kV构支架及设备基础/构架及基础"},{"_id":"{261B1EEB-D461-4DDE-B4F8-494867BEDE70}","nodeType":"项目划分","parentId":"{A51A777A-ED22-48BC-B7A2-311FD782EE1E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.7.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811207200","路径":"建筑工程/主要生产工程/配电装置建筑/220kV构支架及设备基础/支架及基础"},{"_id":"{5070A6CF-A63C-4CD1-A040-2C013D3133E2}","nodeType":"项目划分","parentId":"{A51A777A-ED22-48BC-B7A2-311FD782EE1E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.7.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811207300","路径":"建筑工程/主要生产工程/配电装置建筑/220kV构支架及设备基础/设备基础"},{"_id":"{C061D02F-2718-45EB-A01A-96D2979AA285}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"110kV构支架及设备基础","备注":"","序号":"2.8","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811208000","路径":"建筑工程/主要生产工程/配电装置建筑/110kV构支架及设备基础"},{"_id":"{137BDEB3-6344-450A-BDD2-9D43D0432617}","nodeType":"项目划分","parentId":"{C061D02F-2718-45EB-A01A-96D2979AA285}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.8.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811208100","路径":"建筑工程/主要生产工程/配电装置建筑/110kV构支架及设备基础/构架及基础"},{"_id":"{66BF8E54-DF24-47D8-8AF3-17D906387E87}","nodeType":"项目划分","parentId":"{C061D02F-2718-45EB-A01A-96D2979AA285}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.8.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811208200","路径":"建筑工程/主要生产工程/配电装置建筑/110kV构支架及设备基础/支架及基础"},{"_id":"{5059BCAF-C4FE-48D7-ADDA-4FEEF6535429}","nodeType":"项目划分","parentId":"{C061D02F-2718-45EB-A01A-96D2979AA285}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.8.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811208300","路径":"建筑工程/主要生产工程/配电装置建筑/110kV构支架及设备基础/设备基础"},{"_id":"{31B441D0-BA0C-4DFA-AD11-998EB38A3894}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"66kV构支架及设备基础","备注":"","序号":"2.9","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811209000","路径":"建筑工程/主要生产工程/配电装置建筑/66kV构支架及设备基础"},{"_id":"{0FC10452-C292-4590-A069-2EC8344CB7F1}","nodeType":"项目划分","parentId":"{31B441D0-BA0C-4DFA-AD11-998EB38A3894}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.9.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811209100","路径":"建筑工程/主要生产工程/配电装置建筑/66kV构支架及设备基础/构架及基础"},{"_id":"{34B79EE9-B016-4240-8042-6C6A9511837A}","nodeType":"项目划分","parentId":"{31B441D0-BA0C-4DFA-AD11-998EB38A3894}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.9.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811209200","路径":"建筑工程/主要生产工程/配电装置建筑/66kV构支架及设备基础/支架及基础"},{"_id":"{70A0637D-F120-4669-B2F0-700106985830}","nodeType":"项目划分","parentId":"{31B441D0-BA0C-4DFA-AD11-998EB38A3894}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.9.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811209300","路径":"建筑工程/主要生产工程/配电装置建筑/66kV构支架及设备基础/设备基础"},{"_id":"{4FD749F0-7CEF-4DEA-B513-2ADA929B23ED}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"35kV构支架及设备基础","备注":"","序号":"2.10","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811210000","路径":"建筑工程/主要生产工程/配电装置建筑/35kV构支架及设备基础"},{"_id":"{CE780965-218D-4AAD-BAD1-E2ECE7F9D992}","nodeType":"项目划分","parentId":"{4FD749F0-7CEF-4DEA-B513-2ADA929B23ED}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.10.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811210100","路径":"建筑工程/主要生产工程/配电装置建筑/35kV构支架及设备基础/构架及基础"},{"_id":"{0E4EF75E-B7ED-4A3D-89FA-2E6A2A8FD938}","nodeType":"项目划分","parentId":"{4FD749F0-7CEF-4DEA-B513-2ADA929B23ED}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.10.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811210200","路径":"建筑工程/主要生产工程/配电装置建筑/35kV构支架及设备基础/支架及基础"},{"_id":"{00721787-A7FC-43F5-80CF-A12B3E7CD410}","nodeType":"项目划分","parentId":"{4FD749F0-7CEF-4DEA-B513-2ADA929B23ED}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.10.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811210300","路径":"建筑工程/主要生产工程/配电装置建筑/35kV构支架及设备基础/设备基础"},{"_id":"{98651441-074D-4D8B-BAC2-5D707B6432D1}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"20kV构支架及设备基础","备注":"","序号":"2.11","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811211000","路径":"建筑工程/主要生产工程/配电装置建筑/20kV构支架及设备基础"},{"_id":"{5D973DAB-270A-4D7C-A54E-65EEA305CEDD}","nodeType":"项目划分","parentId":"{98651441-074D-4D8B-BAC2-5D707B6432D1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.11.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811211100","路径":"建筑工程/主要生产工程/配电装置建筑/20kV构支架及设备基础/构架及基础"},{"_id":"{5733E1C9-D382-41BA-8EA2-0FF43994C16C}","nodeType":"项目划分","parentId":"{98651441-074D-4D8B-BAC2-5D707B6432D1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.11.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811211200","路径":"建筑工程/主要生产工程/配电装置建筑/20kV构支架及设备基础/支架及基础"},{"_id":"{98F0FA81-6E7B-470D-A9E1-7EF716031530}","nodeType":"项目划分","parentId":"{98651441-074D-4D8B-BAC2-5D707B6432D1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.11.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811211300","路径":"建筑工程/主要生产工程/配电装置建筑/20kV构支架及设备基础/设备基础"},{"_id":"{D682DA49-87E8-40DE-A196-48F70988A6C2}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"10kV构支架及设备基础","备注":"","序号":"2.12","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811212000","路径":"建筑工程/主要生产工程/配电装置建筑/10kV构支架及设备基础"},{"_id":"{C0CB8F7C-F697-4144-A70E-DF206DB61644}","nodeType":"项目划分","parentId":"{D682DA49-87E8-40DE-A196-48F70988A6C2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"构架及基础","备注":"","序号":"2.12.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811212100","路径":"建筑工程/主要生产工程/配电装置建筑/10kV构支架及设备基础/构架及基础"},{"_id":"{BE7C4BAB-050D-48D7-8FCC-A34E0351CFA3}","nodeType":"项目划分","parentId":"{D682DA49-87E8-40DE-A196-48F70988A6C2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/t(m³)","取费表":"建筑取费表","合价":"0","名称":"支架及基础","备注":"","序号":"2.12.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811212200","路径":"建筑工程/主要生产工程/配电装置建筑/10kV构支架及设备基础/支架及基础"},{"_id":"{E4564EF8-A98B-4EE3-8D09-E570F6BA8341}","nodeType":"项目划分","parentId":"{D682DA49-87E8-40DE-A196-48F70988A6C2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"设备基础","备注":"","序号":"2.12.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811212300","路径":"建筑工程/主要生产工程/配电装置建筑/10kV构支架及设备基础/设备基础"},{"_id":"{AC3766C8-CE10-4881-A654-961BDD26EE9E}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"1000kV高压电抗器系统","备注":"","序号":"2.13","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811213000","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV高压电抗器系统"},{"_id":"{40E189A4-C68F-4D7A-9412-3C414C77C004}","nodeType":"项目划分","parentId":"{AC3766C8-CE10-4881-A654-961BDD26EE9E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.13.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811213100","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV高压电抗器系统/构支架及基础"},{"_id":"{3A94445A-5CD5-4E89-9FD3-E179563AF5D0}","nodeType":"项目划分","parentId":"{AC3766C8-CE10-4881-A654-961BDD26EE9E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.13.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811213200","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{74BB69B3-57E2-4F39-B7E3-369D3BAFF9D7}","nodeType":"项目划分","parentId":"{AC3766C8-CE10-4881-A654-961BDD26EE9E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.13.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811213300","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{8B2B4D22-50AB-4739-A0A8-1058561CD506}","nodeType":"项目划分","parentId":"{AC3766C8-CE10-4881-A654-961BDD26EE9E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.13.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811213400","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV高压电抗器系统/防火墙"},{"_id":"{32BA5B5D-1B35-4C2C-88B0-525398EBDC6B}","nodeType":"项目划分","parentId":"{AC3766C8-CE10-4881-A654-961BDD26EE9E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.13.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811213500","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV高压电抗器系统/xxm³事故油池"},{"_id":"{47240D41-69BC-471E-8893-9D4C2DB7D6C6}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"750kV高压电抗器系统","备注":"","序号":"2.14","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811214000","路径":"建筑工程/主要生产工程/配电装置建筑/750kV高压电抗器系统"},{"_id":"{509708D3-C46E-4E62-97C0-0BF333133933}","nodeType":"项目划分","parentId":"{47240D41-69BC-471E-8893-9D4C2DB7D6C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.14.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811214100","路径":"建筑工程/主要生产工程/配电装置建筑/750kV高压电抗器系统/构支架及基础"},{"_id":"{B1F8EE30-62AA-4BD7-B270-6452EE1D6B2B}","nodeType":"项目划分","parentId":"{47240D41-69BC-471E-8893-9D4C2DB7D6C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.14.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811214200","路径":"建筑工程/主要生产工程/配电装置建筑/750kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{3C78299A-A3D5-4BF2-B001-59C95854BAAF}","nodeType":"项目划分","parentId":"{47240D41-69BC-471E-8893-9D4C2DB7D6C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.14.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811214300","路径":"建筑工程/主要生产工程/配电装置建筑/750kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{4F6EE54F-6F2E-44C8-AFA5-0DC7552375CE}","nodeType":"项目划分","parentId":"{47240D41-69BC-471E-8893-9D4C2DB7D6C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.14.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811214400","路径":"建筑工程/主要生产工程/配电装置建筑/750kV高压电抗器系统/防火墙"},{"_id":"{C98C860C-44BB-4047-B38D-8862136B2679}","nodeType":"项目划分","parentId":"{47240D41-69BC-471E-8893-9D4C2DB7D6C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.14.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811214500","路径":"建筑工程/主要生产工程/配电装置建筑/750kV高压电抗器系统/xxm³事故油池"},{"_id":"{2BA35C80-FA20-43E0-BEC8-942E83D464D6}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"660kV高压电抗器系统","备注":"","序号":"2.15","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811215000","路径":"建筑工程/主要生产工程/配电装置建筑/660kV高压电抗器系统"},{"_id":"{4606D7CF-509E-4236-BAD9-F9A182F9CA86}","nodeType":"项目划分","parentId":"{2BA35C80-FA20-43E0-BEC8-942E83D464D6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.15.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811215100","路径":"建筑工程/主要生产工程/配电装置建筑/660kV高压电抗器系统/构支架及基础"},{"_id":"{1EC474E0-A847-41C2-A444-9D10FB210D5F}","nodeType":"项目划分","parentId":"{2BA35C80-FA20-43E0-BEC8-942E83D464D6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.15.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811215200","路径":"建筑工程/主要生产工程/配电装置建筑/660kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{D5180168-6621-4CEE-8EE0-33457FC0F403}","nodeType":"项目划分","parentId":"{2BA35C80-FA20-43E0-BEC8-942E83D464D6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.15.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811215300","路径":"建筑工程/主要生产工程/配电装置建筑/660kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{4DFF05CC-B876-4BDE-8FBD-D8A869CEE981}","nodeType":"项目划分","parentId":"{2BA35C80-FA20-43E0-BEC8-942E83D464D6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.15.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811215400","路径":"建筑工程/主要生产工程/配电装置建筑/660kV高压电抗器系统/防火墙"},{"_id":"{37947D23-2AD2-4318-8014-6E3176E3A32C}","nodeType":"项目划分","parentId":"{2BA35C80-FA20-43E0-BEC8-942E83D464D6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.15.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811215500","路径":"建筑工程/主要生产工程/配电装置建筑/660kV高压电抗器系统/xxm³事故油池"},{"_id":"{FDBE1078-B948-4051-BD5E-74EEC2CE3BCC}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"500kV高压电抗器系统","备注":"","序号":"2.16","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811216000","路径":"建筑工程/主要生产工程/配电装置建筑/500kV高压电抗器系统"},{"_id":"{ED71B3F6-DCB3-4A26-821D-72BCEFF1F598}","nodeType":"项目划分","parentId":"{FDBE1078-B948-4051-BD5E-74EEC2CE3BCC}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.16.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811216100","路径":"建筑工程/主要生产工程/配电装置建筑/500kV高压电抗器系统/构支架及基础"},{"_id":"{D2A0D908-D213-4835-818F-C942FAC6B2DB}","nodeType":"项目划分","parentId":"{FDBE1078-B948-4051-BD5E-74EEC2CE3BCC}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.16.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811216200","路径":"建筑工程/主要生产工程/配电装置建筑/500kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{97E80E59-5E2A-4724-8BC2-5577A734D3E0}","nodeType":"项目划分","parentId":"{FDBE1078-B948-4051-BD5E-74EEC2CE3BCC}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.16.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811216300","路径":"建筑工程/主要生产工程/配电装置建筑/500kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{A983DF01-2988-4E01-B591-E36883658DAE}","nodeType":"项目划分","parentId":"{FDBE1078-B948-4051-BD5E-74EEC2CE3BCC}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.16.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811216400","路径":"建筑工程/主要生产工程/配电装置建筑/500kV高压电抗器系统/防火墙"},{"_id":"{CA803113-FED4-4ECE-A7E5-473525842D2B}","nodeType":"项目划分","parentId":"{FDBE1078-B948-4051-BD5E-74EEC2CE3BCC}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.16.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811216500","路径":"建筑工程/主要生产工程/配电装置建筑/500kV高压电抗器系统/xxm³事故油池"},{"_id":"{CDB0DC97-1C62-42ED-9B80-54169AC17AD2}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"330kV高压电抗器系统","备注":"","序号":"2.17","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811217000","路径":"建筑工程/主要生产工程/配电装置建筑/330kV高压电抗器系统"},{"_id":"{7080965E-54FB-461D-996F-A2309259985E}","nodeType":"项目划分","parentId":"{CDB0DC97-1C62-42ED-9B80-54169AC17AD2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.17.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811217100","路径":"建筑工程/主要生产工程/配电装置建筑/330kV高压电抗器系统/构支架及基础"},{"_id":"{D9FC58E1-8919-430A-8CE2-08FBA8AA7C95}","nodeType":"项目划分","parentId":"{CDB0DC97-1C62-42ED-9B80-54169AC17AD2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.17.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811217200","路径":"建筑工程/主要生产工程/配电装置建筑/330kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{035F097B-CB08-4A3A-9816-B91EF83A56F2}","nodeType":"项目划分","parentId":"{CDB0DC97-1C62-42ED-9B80-54169AC17AD2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.17.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811217300","路径":"建筑工程/主要生产工程/配电装置建筑/330kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{0FE03012-A983-44C8-A279-603B69D58143}","nodeType":"项目划分","parentId":"{CDB0DC97-1C62-42ED-9B80-54169AC17AD2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.17.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811217400","路径":"建筑工程/主要生产工程/配电装置建筑/330kV高压电抗器系统/防火墙"},{"_id":"{8FA978BD-1D65-4972-8D88-9920F0ADF8CA}","nodeType":"项目划分","parentId":"{CDB0DC97-1C62-42ED-9B80-54169AC17AD2}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.17.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811217500","路径":"建筑工程/主要生产工程/配电装置建筑/330kV高压电抗器系统/xxm³事故油池"},{"_id":"{444E8320-FCEC-4E0A-94F7-5EBF4226AF7A}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"220kV高压电抗器系统","备注":"","序号":"2.18","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811218000","路径":"建筑工程/主要生产工程/配电装置建筑/220kV高压电抗器系统"},{"_id":"{37A1AD10-4D61-422D-966D-205EDC4AD439}","nodeType":"项目划分","parentId":"{444E8320-FCEC-4E0A-94F7-5EBF4226AF7A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.18.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811218100","路径":"建筑工程/主要生产工程/配电装置建筑/220kV高压电抗器系统/构支架及基础"},{"_id":"{01417DBD-D6CC-41FE-B33F-860913BA84D7}","nodeType":"项目划分","parentId":"{444E8320-FCEC-4E0A-94F7-5EBF4226AF7A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.18.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811218200","路径":"建筑工程/主要生产工程/配电装置建筑/220kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{17CD9A36-7579-4F37-AF5E-40915D98E36F}","nodeType":"项目划分","parentId":"{444E8320-FCEC-4E0A-94F7-5EBF4226AF7A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.18.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811218300","路径":"建筑工程/主要生产工程/配电装置建筑/220kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{75616FC4-A0CF-4B33-8961-0B4D16B3DBF9}","nodeType":"项目划分","parentId":"{444E8320-FCEC-4E0A-94F7-5EBF4226AF7A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.18.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811218400","路径":"建筑工程/主要生产工程/配电装置建筑/220kV高压电抗器系统/防火墙"},{"_id":"{31A1A364-D7AF-4282-89CA-194AAE30792E}","nodeType":"项目划分","parentId":"{444E8320-FCEC-4E0A-94F7-5EBF4226AF7A}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.18.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811218500","路径":"建筑工程/主要生产工程/配电装置建筑/220kV高压电抗器系统/xxm³事故油池"},{"_id":"{86963645-129A-4F78-8D70-405BA20498DE}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"110kV高压电抗器系统","备注":"","序号":"2.19","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811219000","路径":"建筑工程/主要生产工程/配电装置建筑/110kV高压电抗器系统"},{"_id":"{99C1E613-C59E-4C1B-B0BA-65F314A29C51}","nodeType":"项目划分","parentId":"{86963645-129A-4F78-8D70-405BA20498DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.19.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811219100","路径":"建筑工程/主要生产工程/配电装置建筑/110kV高压电抗器系统/构支架及基础"},{"_id":"{578BD7C0-94F6-4A45-9BAC-A18434FEC87B}","nodeType":"项目划分","parentId":"{86963645-129A-4F78-8D70-405BA20498DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.19.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811219200","路径":"建筑工程/主要生产工程/配电装置建筑/110kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{35655612-6657-4E58-80A4-4F990AC516F2}","nodeType":"项目划分","parentId":"{86963645-129A-4F78-8D70-405BA20498DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.19.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811219300","路径":"建筑工程/主要生产工程/配电装置建筑/110kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{A7EC4354-848D-4030-B6BD-7B28A6F11D6F}","nodeType":"项目划分","parentId":"{86963645-129A-4F78-8D70-405BA20498DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.19.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811219400","路径":"建筑工程/主要生产工程/配电装置建筑/110kV高压电抗器系统/防火墙"},{"_id":"{5F0F5997-BC4F-422D-ABE2-ECF3790801F7}","nodeType":"项目划分","parentId":"{86963645-129A-4F78-8D70-405BA20498DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.19.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811219500","路径":"建筑工程/主要生产工程/配电装置建筑/110kV高压电抗器系统/xxm³事故油池"},{"_id":"{AC96AFCF-1A33-4051-A56B-2B32020366E5}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"66kV高压电抗器系统","备注":"","序号":"2.20","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811220000","路径":"建筑工程/主要生产工程/配电装置建筑/66kV高压电抗器系统"},{"_id":"{28304E45-FD6A-4894-95EB-9A4CAA22D22E}","nodeType":"项目划分","parentId":"{AC96AFCF-1A33-4051-A56B-2B32020366E5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.20.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811220100","路径":"建筑工程/主要生产工程/配电装置建筑/66kV高压电抗器系统/构支架及基础"},{"_id":"{F3EB9E27-A303-4880-B614-600E88765899}","nodeType":"项目划分","parentId":"{AC96AFCF-1A33-4051-A56B-2B32020366E5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.20.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811220200","路径":"建筑工程/主要生产工程/配电装置建筑/66kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{0BB68C49-18C8-444B-8581-244A6A40F8C9}","nodeType":"项目划分","parentId":"{AC96AFCF-1A33-4051-A56B-2B32020366E5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.20.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811220300","路径":"建筑工程/主要生产工程/配电装置建筑/66kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{022BF1AA-EE05-47AE-91FE-DA08F9F915CB}","nodeType":"项目划分","parentId":"{AC96AFCF-1A33-4051-A56B-2B32020366E5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.20.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811220400","路径":"建筑工程/主要生产工程/配电装置建筑/66kV高压电抗器系统/防火墙"},{"_id":"{3C1623B9-608F-4C52-91AE-2195EA6DFC9C}","nodeType":"项目划分","parentId":"{AC96AFCF-1A33-4051-A56B-2B32020366E5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.20.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811220500","路径":"建筑工程/主要生产工程/配电装置建筑/66kV高压电抗器系统/xxm³事故油池"},{"_id":"{10DFB682-7A82-4F6D-8F91-9FE0BCBF30AA}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"35kV高压电抗器系统","备注":"","序号":"2.21","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811221000","路径":"建筑工程/主要生产工程/配电装置建筑/35kV高压电抗器系统"},{"_id":"{C9EF9F2C-2DDF-44D7-92B7-835E7AA4BB07}","nodeType":"项目划分","parentId":"{10DFB682-7A82-4F6D-8F91-9FE0BCBF30AA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.21.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811221100","路径":"建筑工程/主要生产工程/配电装置建筑/35kV高压电抗器系统/构支架及基础"},{"_id":"{D5160053-8B33-434C-BBCC-2CE2F9C834FC}","nodeType":"项目划分","parentId":"{10DFB682-7A82-4F6D-8F91-9FE0BCBF30AA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.21.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811221200","路径":"建筑工程/主要生产工程/配电装置建筑/35kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{C72921A2-FD99-4517-99A5-2D1735740AF3}","nodeType":"项目划分","parentId":"{10DFB682-7A82-4F6D-8F91-9FE0BCBF30AA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.21.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811221300","路径":"建筑工程/主要生产工程/配电装置建筑/35kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{6977AEB9-14F5-4720-B17E-7BB9DB30A373}","nodeType":"项目划分","parentId":"{10DFB682-7A82-4F6D-8F91-9FE0BCBF30AA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.21.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811221400","路径":"建筑工程/主要生产工程/配电装置建筑/35kV高压电抗器系统/防火墙"},{"_id":"{F5364F23-340F-4704-B57A-85501BC38BF1}","nodeType":"项目划分","parentId":"{10DFB682-7A82-4F6D-8F91-9FE0BCBF30AA}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.21.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811221500","路径":"建筑工程/主要生产工程/配电装置建筑/35kV高压电抗器系统/xxm³事故油池"},{"_id":"{3882F2E7-732B-4CF4-A660-4E8E692F345F}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"20kV高压电抗器系统","备注":"","序号":"2.22","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811222000","路径":"建筑工程/主要生产工程/配电装置建筑/20kV高压电抗器系统"},{"_id":"{B48B6FA7-397F-4D2A-BB4F-5A77DEE9E047}","nodeType":"项目划分","parentId":"{3882F2E7-732B-4CF4-A660-4E8E692F345F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.22.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811222100","路径":"建筑工程/主要生产工程/配电装置建筑/20kV高压电抗器系统/构支架及基础"},{"_id":"{DE1BBFB3-B0C2-4966-B496-3C9CEE1C51B5}","nodeType":"项目划分","parentId":"{3882F2E7-732B-4CF4-A660-4E8E692F345F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.22.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811222200","路径":"建筑工程/主要生产工程/配电装置建筑/20kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{0E9E0D9E-779C-4D0E-BE7B-9E14DDD61EFA}","nodeType":"项目划分","parentId":"{3882F2E7-732B-4CF4-A660-4E8E692F345F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.22.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811222300","路径":"建筑工程/主要生产工程/配电装置建筑/20kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{5A36320C-3C7B-4D55-AE8B-9C9DF5209688}","nodeType":"项目划分","parentId":"{3882F2E7-732B-4CF4-A660-4E8E692F345F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.22.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811222400","路径":"建筑工程/主要生产工程/配电装置建筑/20kV高压电抗器系统/防火墙"},{"_id":"{990D1029-1F97-4B5D-94C0-37C964E22E90}","nodeType":"项目划分","parentId":"{3882F2E7-732B-4CF4-A660-4E8E692F345F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.22.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811222500","路径":"建筑工程/主要生产工程/配电装置建筑/20kV高压电抗器系统/xxm³事故油池"},{"_id":"{4F138528-A199-4553-A5A2-E2EE451B28E6}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"","合价":"0","名称":"10kV高压电抗器系统","备注":"","序号":"2.23","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811223000","路径":"建筑工程/主要生产工程/配电装置建筑/10kV高压电抗器系统"},{"_id":"{3D1AA9E9-0135-4F1F-A7C3-93D259D577EE}","nodeType":"项目划分","parentId":"{4F138528-A199-4553-A5A2-E2EE451B28E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.23.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811223100","路径":"建筑工程/主要生产工程/配电装置建筑/10kV高压电抗器系统/构支架及基础"},{"_id":"{C6F35769-C17A-44CC-8664-4F76AECBBEE5}","nodeType":"项目划分","parentId":"{4F138528-A199-4553-A5A2-E2EE451B28E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高压电抗器设备基础","备注":"","序号":"2.23.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811223200","路径":"建筑工程/主要生产工程/配电装置建筑/10kV高压电抗器系统/高压电抗器设备基础"},{"_id":"{9C1CE574-8183-4A1E-A69C-6775B0CF5B70}","nodeType":"项目划分","parentId":"{4F138528-A199-4553-A5A2-E2EE451B28E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"高抗油坑及卵石","备注":"","序号":"2.23.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811223300","路径":"建筑工程/主要生产工程/配电装置建筑/10kV高压电抗器系统/高抗油坑及卵石"},{"_id":"{4A1ABF01-2203-4232-9115-F5F07007B756}","nodeType":"项目划分","parentId":"{4F138528-A199-4553-A5A2-E2EE451B28E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.23.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811223400","路径":"建筑工程/主要生产工程/配电装置建筑/10kV高压电抗器系统/防火墙"},{"_id":"{B4786932-78B2-479D-8CF3-BC1C11244F81}","nodeType":"项目划分","parentId":"{4F138528-A199-4553-A5A2-E2EE451B28E6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"xxm³事故油池","备注":"","序号":"2.23.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811223500","路径":"建筑工程/主要生产工程/配电装置建筑/10kV高压电抗器系统/xxm³事故油池"},{"_id":"{A0ABE923-0E84-4C2D-B619-0DC4580877B0}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"1000kV串联补偿系统","备注":"","序号":"2.24","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811224000","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV串联补偿系统"},{"_id":"{9255D826-BADC-46D0-8D4B-151B08B403A0}","nodeType":"项目划分","parentId":"{A0ABE923-0E84-4C2D-B619-0DC4580877B0}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.24.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811224100","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{D7328BD6-6729-4BF6-8A97-4ECF44233221}","nodeType":"项目划分","parentId":"{A0ABE923-0E84-4C2D-B619-0DC4580877B0}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.24.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811224200","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{C9F2B9F2-A8F3-416C-A020-8AA802641940}","nodeType":"项目划分","parentId":"{A0ABE923-0E84-4C2D-B619-0DC4580877B0}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.24.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811224300","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV串联补偿系统/构支架及基础"},{"_id":"{8444ED78-BD66-4D76-9FA3-116B6F06E134}","nodeType":"项目划分","parentId":"{A0ABE923-0E84-4C2D-B619-0DC4580877B0}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.24.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811224400","路径":"建筑工程/主要生产工程/配电装置建筑/1000kV串联补偿系统/设备支架及基础"},{"_id":"{9B5D6A2A-9FD3-4104-8902-F29E24C252C7}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"750kV串联补偿系统","备注":"","序号":"2.25","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811225000","路径":"建筑工程/主要生产工程/配电装置建筑/750kV串联补偿系统"},{"_id":"{52480622-B04A-45F4-A14C-43635667E43F}","nodeType":"项目划分","parentId":"{9B5D6A2A-9FD3-4104-8902-F29E24C252C7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.25.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811225100","路径":"建筑工程/主要生产工程/配电装置建筑/750kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{7D352412-0ACA-4CC8-A7E9-F236DDE4F91F}","nodeType":"项目划分","parentId":"{9B5D6A2A-9FD3-4104-8902-F29E24C252C7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.25.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811225200","路径":"建筑工程/主要生产工程/配电装置建筑/750kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{24FFF363-CB89-422F-823A-2E7625DD7AF0}","nodeType":"项目划分","parentId":"{9B5D6A2A-9FD3-4104-8902-F29E24C252C7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.25.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811225300","路径":"建筑工程/主要生产工程/配电装置建筑/750kV串联补偿系统/构支架及基础"},{"_id":"{BF4337AD-6678-461D-B4CB-7BCA3F5BC75A}","nodeType":"项目划分","parentId":"{9B5D6A2A-9FD3-4104-8902-F29E24C252C7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.25.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811225400","路径":"建筑工程/主要生产工程/配电装置建筑/750kV串联补偿系统/设备支架及基础"},{"_id":"{77F62A1F-FC04-4998-B136-4D6A47CD7F1B}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"660kV串联补偿系统","备注":"","序号":"2.26","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811226000","路径":"建筑工程/主要生产工程/配电装置建筑/660kV串联补偿系统"},{"_id":"{7E45AB77-9937-4F55-98CF-FCADBD0EF2D4}","nodeType":"项目划分","parentId":"{77F62A1F-FC04-4998-B136-4D6A47CD7F1B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.26.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811226100","路径":"建筑工程/主要生产工程/配电装置建筑/660kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{F81E6614-978B-43C4-A719-BB0F6C8CCC62}","nodeType":"项目划分","parentId":"{77F62A1F-FC04-4998-B136-4D6A47CD7F1B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.26.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811226200","路径":"建筑工程/主要生产工程/配电装置建筑/660kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{C1B0ABE2-401A-4155-85C2-333BD366131F}","nodeType":"项目划分","parentId":"{77F62A1F-FC04-4998-B136-4D6A47CD7F1B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.26.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811226300","路径":"建筑工程/主要生产工程/配电装置建筑/660kV串联补偿系统/构支架及基础"},{"_id":"{50A8D63D-A9F5-43C7-BD58-77364616BF5B}","nodeType":"项目划分","parentId":"{77F62A1F-FC04-4998-B136-4D6A47CD7F1B}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.26.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811226400","路径":"建筑工程/主要生产工程/配电装置建筑/660kV串联补偿系统/设备支架及基础"},{"_id":"{23F26411-7128-418B-8334-42E2F99B52A5}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"500kV串联补偿系统","备注":"","序号":"2.27","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811227000","路径":"建筑工程/主要生产工程/配电装置建筑/500kV串联补偿系统"},{"_id":"{685E55BD-3CFC-49D6-9C27-FFDE35940571}","nodeType":"项目划分","parentId":"{23F26411-7128-418B-8334-42E2F99B52A5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.27.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811227100","路径":"建筑工程/主要生产工程/配电装置建筑/500kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{80FA8333-F46C-4CC7-A238-67C3F9FBAB34}","nodeType":"项目划分","parentId":"{23F26411-7128-418B-8334-42E2F99B52A5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.27.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811227200","路径":"建筑工程/主要生产工程/配电装置建筑/500kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{F329877B-12CB-4382-A051-617AA1BAB17B}","nodeType":"项目划分","parentId":"{23F26411-7128-418B-8334-42E2F99B52A5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.27.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811227300","路径":"建筑工程/主要生产工程/配电装置建筑/500kV串联补偿系统/构支架及基础"},{"_id":"{F8225044-19B0-495C-8E32-96BED3650F28}","nodeType":"项目划分","parentId":"{23F26411-7128-418B-8334-42E2F99B52A5}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.27.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811227400","路径":"建筑工程/主要生产工程/配电装置建筑/500kV串联补偿系统/设备支架及基础"},{"_id":"{7E9197D2-73F5-4A80-9BCE-550A45431804}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"330kV串联补偿系统","备注":"","序号":"2.28","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811228000","路径":"建筑工程/主要生产工程/配电装置建筑/330kV串联补偿系统"},{"_id":"{C489CF37-5B9E-4904-84DF-278CC4A9FA01}","nodeType":"项目划分","parentId":"{7E9197D2-73F5-4A80-9BCE-550A45431804}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.28.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811228100","路径":"建筑工程/主要生产工程/配电装置建筑/330kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{47CF1CCA-D2FC-4D52-A693-F51AB4407A9D}","nodeType":"项目划分","parentId":"{7E9197D2-73F5-4A80-9BCE-550A45431804}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.28.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811228200","路径":"建筑工程/主要生产工程/配电装置建筑/330kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{55E68B60-5200-4597-A9DC-97CBE4D05998}","nodeType":"项目划分","parentId":"{7E9197D2-73F5-4A80-9BCE-550A45431804}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.28.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811228300","路径":"建筑工程/主要生产工程/配电装置建筑/330kV串联补偿系统/构支架及基础"},{"_id":"{90E6B1F4-450F-40F5-ABEE-B53CFCC2F80F}","nodeType":"项目划分","parentId":"{7E9197D2-73F5-4A80-9BCE-550A45431804}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.28.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811228400","路径":"建筑工程/主要生产工程/配电装置建筑/330kV串联补偿系统/设备支架及基础"},{"_id":"{9DF29CFB-5D80-4DD5-88BB-C625BBC0C079}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"220kV串联补偿系统","备注":"","序号":"2.29","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811229000","路径":"建筑工程/主要生产工程/配电装置建筑/220kV串联补偿系统"},{"_id":"{06491FC6-E82B-4657-B885-7C159DD8C242}","nodeType":"项目划分","parentId":"{9DF29CFB-5D80-4DD5-88BB-C625BBC0C079}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.29.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811229100","路径":"建筑工程/主要生产工程/配电装置建筑/220kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{8B1A22C5-CD7A-468E-AF1B-154C0F1D3919}","nodeType":"项目划分","parentId":"{9DF29CFB-5D80-4DD5-88BB-C625BBC0C079}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.29.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811229200","路径":"建筑工程/主要生产工程/配电装置建筑/220kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{3EF74439-7E6C-4205-AFB1-8A90E25D0F2F}","nodeType":"项目划分","parentId":"{9DF29CFB-5D80-4DD5-88BB-C625BBC0C079}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.29.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811229300","路径":"建筑工程/主要生产工程/配电装置建筑/220kV串联补偿系统/构支架及基础"},{"_id":"{A0256473-0590-4670-8D12-48D9368FF8CC}","nodeType":"项目划分","parentId":"{9DF29CFB-5D80-4DD5-88BB-C625BBC0C079}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.29.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811229400","路径":"建筑工程/主要生产工程/配电装置建筑/220kV串联补偿系统/设备支架及基础"},{"_id":"{E0625C79-34F0-466B-8B66-34B6EC6C02FB}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"110kV串联补偿系统","备注":"","序号":"2.30","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811230000","路径":"建筑工程/主要生产工程/配电装置建筑/110kV串联补偿系统"},{"_id":"{3EFC999E-25E7-43BC-81C4-CD23164F989A}","nodeType":"项目划分","parentId":"{E0625C79-34F0-466B-8B66-34B6EC6C02FB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.30.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811230100","路径":"建筑工程/主要生产工程/配电装置建筑/110kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{2EA4384F-201C-41D8-89C4-BF311AED2410}","nodeType":"项目划分","parentId":"{E0625C79-34F0-466B-8B66-34B6EC6C02FB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.30.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811230200","路径":"建筑工程/主要生产工程/配电装置建筑/110kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{70616EF8-088D-408F-B26D-070A9B0C84C8}","nodeType":"项目划分","parentId":"{E0625C79-34F0-466B-8B66-34B6EC6C02FB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.30.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811230300","路径":"建筑工程/主要生产工程/配电装置建筑/110kV串联补偿系统/构支架及基础"},{"_id":"{D981F2C1-44B9-45A1-BE6C-714E6F2FF68D}","nodeType":"项目划分","parentId":"{E0625C79-34F0-466B-8B66-34B6EC6C02FB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.30.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811230400","路径":"建筑工程/主要生产工程/配电装置建筑/110kV串联补偿系统/设备支架及基础"},{"_id":"{284F55A1-7A1E-429E-BE02-E9C0D545BC65}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"66kV串联补偿系统","备注":"","序号":"2.31","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811231000","路径":"建筑工程/主要生产工程/配电装置建筑/66kV串联补偿系统"},{"_id":"{BC26E905-30F6-4DC9-AE8C-3501D10C63D0}","nodeType":"项目划分","parentId":"{284F55A1-7A1E-429E-BE02-E9C0D545BC65}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.31.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811231100","路径":"建筑工程/主要生产工程/配电装置建筑/66kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{934B3140-18FC-4FC2-87AC-D02706EF57A5}","nodeType":"项目划分","parentId":"{284F55A1-7A1E-429E-BE02-E9C0D545BC65}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.31.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811231200","路径":"建筑工程/主要生产工程/配电装置建筑/66kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{CAC17528-6217-4BA1-9F8F-A40B146280D5}","nodeType":"项目划分","parentId":"{284F55A1-7A1E-429E-BE02-E9C0D545BC65}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.31.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811231300","路径":"建筑工程/主要生产工程/配电装置建筑/66kV串联补偿系统/构支架及基础"},{"_id":"{ADE00680-E82D-4D5E-AD54-EC9A247BE8D5}","nodeType":"项目划分","parentId":"{284F55A1-7A1E-429E-BE02-E9C0D545BC65}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.31.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811231400","路径":"建筑工程/主要生产工程/配电装置建筑/66kV串联补偿系统/设备支架及基础"},{"_id":"{600BDECB-EBA3-40EA-B8C4-76FC15C3A979}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"35kV串联补偿系统","备注":"","序号":"2.32","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811232000","路径":"建筑工程/主要生产工程/配电装置建筑/35kV串联补偿系统"},{"_id":"{F011F82E-3153-4AD7-9180-A17FBF3696F3}","nodeType":"项目划分","parentId":"{600BDECB-EBA3-40EA-B8C4-76FC15C3A979}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.32.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811232100","路径":"建筑工程/主要生产工程/配电装置建筑/35kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{E0F5378D-0CF8-40BE-8348-DBAF56AD4269}","nodeType":"项目划分","parentId":"{600BDECB-EBA3-40EA-B8C4-76FC15C3A979}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.32.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811232200","路径":"建筑工程/主要生产工程/配电装置建筑/35kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{F9E35035-B0EC-4A64-B6B2-7100F27F0CFB}","nodeType":"项目划分","parentId":"{600BDECB-EBA3-40EA-B8C4-76FC15C3A979}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.32.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811232300","路径":"建筑工程/主要生产工程/配电装置建筑/35kV串联补偿系统/构支架及基础"},{"_id":"{9C43AEA7-13D4-4845-BBFD-51FF22FCDC17}","nodeType":"项目划分","parentId":"{600BDECB-EBA3-40EA-B8C4-76FC15C3A979}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.32.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811232400","路径":"建筑工程/主要生产工程/配电装置建筑/35kV串联补偿系统/设备支架及基础"},{"_id":"{DB851183-31B1-4DA6-B2C7-AC991E0D0E55}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"20kV串联补偿系统","备注":"","序号":"2.33","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811233000","路径":"建筑工程/主要生产工程/配电装置建筑/20kV串联补偿系统"},{"_id":"{7F74CD42-58E6-4B4C-BF22-C470F76CC3D6}","nodeType":"项目划分","parentId":"{DB851183-31B1-4DA6-B2C7-AC991E0D0E55}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.33.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811233100","路径":"建筑工程/主要生产工程/配电装置建筑/20kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{53EE6ECB-D7C2-4B51-85A3-D031A45D4499}","nodeType":"项目划分","parentId":"{DB851183-31B1-4DA6-B2C7-AC991E0D0E55}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.33.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811233200","路径":"建筑工程/主要生产工程/配电装置建筑/20kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{517F1060-C135-4E14-A387-AF43D5180C97}","nodeType":"项目划分","parentId":"{DB851183-31B1-4DA6-B2C7-AC991E0D0E55}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.33.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811233300","路径":"建筑工程/主要生产工程/配电装置建筑/20kV串联补偿系统/构支架及基础"},{"_id":"{6E7167C2-F17A-45ED-B590-053E280F849C}","nodeType":"项目划分","parentId":"{DB851183-31B1-4DA6-B2C7-AC991E0D0E55}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.33.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811233400","路径":"建筑工程/主要生产工程/配电装置建筑/20kV串联补偿系统/设备支架及基础"},{"_id":"{18FD383E-D6FB-4912-98C3-134B473396E7}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"10kV串联补偿系统","备注":"","序号":"2.34","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811234000","路径":"建筑工程/主要生产工程/配电装置建筑/10kV串联补偿系统"},{"_id":"{CC1D0C54-C4FD-4E08-BC7A-BF52FE3C12D7}","nodeType":"项目划分","parentId":"{18FD383E-D6FB-4912-98C3-134B473396E7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台基础","备注":"","序号":"2.34.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811234100","路径":"建筑工程/主要生产工程/配电装置建筑/10kV串联补偿系统/串联补偿设备平台基础"},{"_id":"{6A19FD9C-9806-4B0A-B8EA-100A497B751C}","nodeType":"项目划分","parentId":"{18FD383E-D6FB-4912-98C3-134B473396E7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"串联补偿设备平台结构","备注":"","序号":"2.34.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811234200","路径":"建筑工程/主要生产工程/配电装置建筑/10kV串联补偿系统/串联补偿设备平台结构"},{"_id":"{65DABEEF-4DAC-4608-8AAB-8C7EAD805882}","nodeType":"项目划分","parentId":"{18FD383E-D6FB-4912-98C3-134B473396E7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.34.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811234300","路径":"建筑工程/主要生产工程/配电装置建筑/10kV串联补偿系统/构支架及基础"},{"_id":"{9B37241D-C30C-4C5E-89C9-D3969A6B2768}","nodeType":"项目划分","parentId":"{18FD383E-D6FB-4912-98C3-134B473396E7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备支架及基础","备注":"","序号":"2.34.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811234400","路径":"建筑工程/主要生产工程/配电装置建筑/10kV串联补偿系统/设备支架及基础"},{"_id":"{53B7764B-40BB-424A-B687-AD57F03613F2}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"建筑取费表","合价":"0","名称":"低压电容器","备注":"","序号":"2.35","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811235000","路径":"建筑工程/主要生产工程/配电装置建筑/低压电容器"},{"_id":"{192913C3-EB32-40D6-A1E4-FD81181E93DF}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/组","取费表":"建筑取费表","合价":"0","名称":"低压电抗器","备注":"","序号":"2.36","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811236000","路径":"建筑工程/主要生产工程/配电装置建筑/低压电抗器"},{"_id":"{1450D288-BA89-4FF2-A68B-BADAC57DA65E}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"静止无功补偿装置","备注":"","序号":"2.37","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811237000","路径":"建筑工程/主要生产工程/配电装置建筑/静止无功补偿装置"},{"_id":"{77BFB9D6-4D1F-47A4-BD28-78002DD47448}","nodeType":"项目划分","parentId":"{1450D288-BA89-4FF2-A68B-BADAC57DA65E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"构支架及基础","备注":"","序号":"2.37.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811237100","路径":"建筑工程/主要生产工程/配电装置建筑/静止无功补偿装置/构支架及基础"},{"_id":"{96E0657A-6474-46B1-AD2C-4A2DEC1C4361}","nodeType":"项目划分","parentId":"{1450D288-BA89-4FF2-A68B-BADAC57DA65E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"静止无功补偿装置设备基础","备注":"","序号":"2.37.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811237200","路径":"建筑工程/主要生产工程/配电装置建筑/静止无功补偿装置/静止无功补偿装置设备基础"},{"_id":"{590AAE5E-9028-49C4-B895-074095D5E518}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/台","取费表":"","合价":"0","名称":"站用变压器系统","备注":"","序号":"2.38","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811238000","路径":"建筑工程/主要生产工程/配电装置建筑/站用变压器系统"},{"_id":"{FDDF20C6-9E3C-4525-843F-A946852ACD32}","nodeType":"项目划分","parentId":"{590AAE5E-9028-49C4-B895-074095D5E518}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"站用变压器设备基础及油坑、卵石","备注":"","序号":"2.38.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811238100","路径":"建筑工程/主要生产工程/配电装置建筑/站用变压器系统/站用变压器设备基础及油坑、卵石"},{"_id":"{C9A62BC8-BE62-4D63-BA0A-DB4FD2E80711}","nodeType":"项目划分","parentId":"{590AAE5E-9028-49C4-B895-074095D5E518}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"防火墙","备注":"","序号":"2.38.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811238200","路径":"建筑工程/主要生产工程/配电装置建筑/站用变压器系统/防火墙"},{"_id":"{A5FF9E9D-A8EB-4B2A-9C33-1BBB40D1B9BE}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"避雷针塔","备注":"","序号":"2.39","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811239000","路径":"建筑工程/主要生产工程/配电装置建筑/避雷针塔"},{"_id":"{EB2BB6DD-F685-4BED-ABD9-75024BD6E2F9}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m","取费表":"建筑取费表","合价":"0","名称":"电缆沟道","备注":"","序号":"2.40","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811240000","路径":"建筑工程/主要生产工程/配电装置建筑/电缆沟道"},{"_id":"{411CE996-5234-4763-A4BC-E5C5A3E64DEC}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"建筑取费表","合价":"0","名称":"栏栅及地坪","备注":"","序号":"2.41","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811241000","路径":"建筑工程/主要生产工程/配电装置建筑/栏栅及地坪"},{"_id":"{E000D691-B401-401E-AD1A-31C16EC7DEFD}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²(m³)","取费表":"建筑取费表","合价":"0","名称":"配电装置区域地面封闭","备注":"","序号":"2.42","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811242000","路径":"建筑工程/主要生产工程/配电装置建筑/配电装置区域地面封闭"},{"_id":"{4F6BB792-4486-472B-B658-AFC0BA6051F1}","nodeType":"项目划分","parentId":"{1AAEF0CB-E43D-4C7A-8362-54659743A374}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"端子箱","备注":"","序号":"2.43","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811243000","路径":"建筑工程/主要生产工程/配电装置建筑/端子箱"},{"_id":"{4D1997D7-098D-409A-B9CE-C34F3B040DF8}","nodeType":"项目划分","parentId":"{CECBFEE2-0081-45F6-8BDC-08CF271B43A1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"供水系统","备注":"","序号":"3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811300000","路径":"建筑工程/主要生产工程/供水系统"},{"_id":"{BBAADC0B-F296-43F9-B423-741909993F5A}","nodeType":"项目划分","parentId":"{4D1997D7-098D-409A-B9CE-C34F3B040DF8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m","取费表":"建筑取费表","合价":"0","名称":"站区供水管道","备注":"","序号":"3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811301000","路径":"建筑工程/主要生产工程/供水系统/站区供水管道"},{"_id":"{BCEAE686-7281-4E1A-BBC3-FDCD4E02FCFD}","nodeType":"项目划分","parentId":"{4D1997D7-098D-409A-B9CE-C34F3B040DF8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"供水系统设备","备注":"","序号":"3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811302000","路径":"建筑工程/主要生产工程/供水系统/供水系统设备"},{"_id":"{1BC684B4-9FFB-4DF9-B5F4-8B21E55F28E3}","nodeType":"项目划分","parentId":"{4D1997D7-098D-409A-B9CE-C34F3B040DF8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"综合水泵房","备注":"","序号":"3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811303000","路径":"建筑工程/主要生产工程/供水系统/综合水泵房"},{"_id":"{B3FCF1B8-4ABF-4706-8691-B55A5DDFCB93}","nodeType":"项目划分","parentId":"{1BC684B4-9FFB-4DF9-B5F4-8B21E55F28E3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"3.3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811303100","路径":"建筑工程/主要生产工程/供水系统/综合水泵房/一般土建"},{"_id":"{F74DD261-41F2-46E6-85D7-7A394869612D}","nodeType":"项目划分","parentId":"{1BC684B4-9FFB-4DF9-B5F4-8B21E55F28E3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备及管道","备注":"","序号":"3.3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811303200","路径":"建筑工程/主要生产工程/供水系统/综合水泵房/设备及管道"},{"_id":"{D7BEDF96-A888-4336-9AC6-355AA4B179A7}","nodeType":"项目划分","parentId":"{1BC684B4-9FFB-4DF9-B5F4-8B21E55F28E3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖及通风","备注":"","序号":"3.3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811303300","路径":"建筑工程/主要生产工程/供水系统/综合水泵房/采暖及通风"},{"_id":"{54FB44C4-A980-4F97-A572-D84DFA140BCC}","nodeType":"项目划分","parentId":"{1BC684B4-9FFB-4DF9-B5F4-8B21E55F28E3}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"3.3.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811303400","路径":"建筑工程/主要生产工程/供水系统/综合水泵房/照明"},{"_id":"{3587CBB6-F184-498A-BB44-898EAF667B85}","nodeType":"项目划分","parentId":"{4D1997D7-098D-409A-B9CE-C34F3B040DF8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"深井","备注":"","序号":"3.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811304000","路径":"建筑工程/主要生产工程/供水系统/深井"},{"_id":"{0F8EF45D-8C0B-4FD3-B77B-7D2ADF3CE873}","nodeType":"项目划分","parentId":"{4D1997D7-098D-409A-B9CE-C34F3B040DF8}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"蓄水池","备注":"","序号":"3.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811305000","路径":"建筑工程/主要生产工程/供水系统/蓄水池"},{"_id":"{38E375BB-B22B-4C38-9641-BC0668465945}","nodeType":"项目划分","parentId":"{CECBFEE2-0081-45F6-8BDC-08CF271B43A1}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"消防系统","备注":"","序号":"4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811400000","路径":"建筑工程/主要生产工程/消防系统"},{"_id":"{690FFF7E-79A9-40F1-A9AC-D00BC498C8C6}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"泡沫消防间","备注":"","序号":"4.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811401000","路径":"建筑工程/主要生产工程/消防系统/泡沫消防间"},{"_id":"{45EED493-E9A1-44C2-8B8A-75D8BB81D0FC}","nodeType":"项目划分","parentId":"{690FFF7E-79A9-40F1-A9AC-D00BC498C8C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"4.1.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811401100","路径":"建筑工程/主要生产工程/消防系统/泡沫消防间/一般土建"},{"_id":"{BD89BB9D-25E9-4EF6-984B-9AE89774C688}","nodeType":"项目划分","parentId":"{690FFF7E-79A9-40F1-A9AC-D00BC498C8C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备及管道","备注":"","序号":"4.1.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811401200","路径":"建筑工程/主要生产工程/消防系统/泡沫消防间/设备及管道"},{"_id":"{24DD25DE-0D79-44E3-9FB8-3660FCBAA10A}","nodeType":"项目划分","parentId":"{690FFF7E-79A9-40F1-A9AC-D00BC498C8C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖及通风","备注":"","序号":"4.1.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811401300","路径":"建筑工程/主要生产工程/消防系统/泡沫消防间/采暖及通风"},{"_id":"{1F453440-0E2A-4B11-A7D7-2D8A5EEE82EB}","nodeType":"项目划分","parentId":"{690FFF7E-79A9-40F1-A9AC-D00BC498C8C6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"4.1.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811401400","路径":"建筑工程/主要生产工程/消防系统/泡沫消防间/照明"},{"_id":"{A8E8B3AD-49FE-4D87-B3FE-8800FC91BDB6}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"消防小间","备注":"","序号":"4.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811402000","路径":"建筑工程/主要生产工程/消防系统/消防小间"},{"_id":"{9CE17420-9804-4F32-B905-747E1754C3A7}","nodeType":"项目划分","parentId":"{A8E8B3AD-49FE-4D87-B3FE-8800FC91BDB6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"4.2.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811402100","路径":"建筑工程/主要生产工程/消防系统/消防小间/一般土建"},{"_id":"{1D908B0E-E979-44B2-AEEE-F9430C0C5E6B}","nodeType":"项目划分","parentId":"{A8E8B3AD-49FE-4D87-B3FE-8800FC91BDB6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备及管道","备注":"","序号":"4.2.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811402200","路径":"建筑工程/主要生产工程/消防系统/消防小间/设备及管道"},{"_id":"{04FE11FF-A662-405C-A124-E9119440FF0F}","nodeType":"项目划分","parentId":"{A8E8B3AD-49FE-4D87-B3FE-8800FC91BDB6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖及通风","备注":"","序号":"4.2.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811402300","路径":"建筑工程/主要生产工程/消防系统/消防小间/采暖及通风"},{"_id":"{9D9EA450-B0FE-481E-8630-5780EAEDBFCC}","nodeType":"项目划分","parentId":"{A8E8B3AD-49FE-4D87-B3FE-8800FC91BDB6}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"4.2.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811402400","路径":"建筑工程/主要生产工程/消防系统/消防小间/照明"},{"_id":"{D0B5B13C-0153-47D8-A473-8DFD1237757E}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"消防水泵房","备注":"","序号":"4.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811403000","路径":"建筑工程/主要生产工程/消防系统/消防水泵房"},{"_id":"{493B4406-D3B4-457D-B821-B2E94D81DAEE}","nodeType":"项目划分","parentId":"{D0B5B13C-0153-47D8-A473-8DFD1237757E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"4.3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811403100","路径":"建筑工程/主要生产工程/消防系统/消防水泵房/一般土建"},{"_id":"{F12264D3-F357-4F47-B345-99144897AB3F}","nodeType":"项目划分","parentId":"{D0B5B13C-0153-47D8-A473-8DFD1237757E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备及管道","备注":"","序号":"4.3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811403200","路径":"建筑工程/主要生产工程/消防系统/消防水泵房/设备及管道"},{"_id":"{5794EDB8-28FB-4711-9A5A-F1F37776B456}","nodeType":"项目划分","parentId":"{D0B5B13C-0153-47D8-A473-8DFD1237757E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖及通风","备注":"","序号":"4.3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811403300","路径":"建筑工程/主要生产工程/消防系统/消防水泵房/采暖及通风"},{"_id":"{6F9648E7-7F54-47D4-919E-DE8D95BEE56D}","nodeType":"项目划分","parentId":"{D0B5B13C-0153-47D8-A473-8DFD1237757E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"4.3.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811403400","路径":"建筑工程/主要生产工程/消防系统/消防水泵房/照明"},{"_id":"{B141DD58-1A5D-48B9-9E9D-3B8CF5D75232}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"雨淋阀室","备注":"","序号":"4.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811404000","路径":"建筑工程/主要生产工程/消防系统/雨淋阀室"},{"_id":"{7174CDC4-3402-49F3-B22F-507C65879B13}","nodeType":"项目划分","parentId":"{B141DD58-1A5D-48B9-9E9D-3B8CF5D75232}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"4.4.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811404100","路径":"建筑工程/主要生产工程/消防系统/雨淋阀室/一般土建"},{"_id":"{EDC93692-CAA6-40EF-919D-C50458DE9BE7}","nodeType":"项目划分","parentId":"{B141DD58-1A5D-48B9-9E9D-3B8CF5D75232}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备及管道","备注":"","序号":"4.4.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811404200","路径":"建筑工程/主要生产工程/消防系统/雨淋阀室/设备及管道"},{"_id":"{541D66E4-124A-4D0C-9139-4E53D5EC4119}","nodeType":"项目划分","parentId":"{B141DD58-1A5D-48B9-9E9D-3B8CF5D75232}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖及通风","备注":"","序号":"4.4.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811404300","路径":"建筑工程/主要生产工程/消防系统/雨淋阀室/采暖及通风"},{"_id":"{A01B614D-A8EF-441B-B3DB-589120CF1C26}","nodeType":"项目划分","parentId":"{B141DD58-1A5D-48B9-9E9D-3B8CF5D75232}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"4.4.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811404400","路径":"建筑工程/主要生产工程/消防系统/雨淋阀室/照明"},{"_id":"{37456432-D132-42C6-BE10-1BF4BC3C6253}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m","取费表":"建筑取费表","合价":"0","名称":"站区消防管路","备注":"","序号":"4.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811405000","路径":"建筑工程/主要生产工程/消防系统/站区消防管路"},{"_id":"{B4849722-E04D-4025-A80A-EB25AA7164F3}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"消防器材","备注":"","序号":"4.6","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811406000","路径":"建筑工程/主要生产工程/消防系统/消防器材"},{"_id":"{714A7F13-5D88-4361-9435-E8AF654F9844}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/台","取费表":"建筑取费表","合价":"0","名称":"特殊消防系统","备注":"","序号":"4.7","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811407000","路径":"建筑工程/主要生产工程/消防系统/特殊消防系统"},{"_id":"{800BDFEB-B2C2-4D9B-B33D-D08E952B092A}","nodeType":"项目划分","parentId":"{38E375BB-B22B-4C38-9641-BC0668465945}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/座","取费表":"建筑取费表","合价":"0","名称":"消防水池","备注":"","序号":"4.8","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21811408000","路径":"建筑工程/主要生产工程/消防系统/消防水池"},{"_id":"{9ECE65BC-FD73-49BC-BE7A-3119ECD8923F}","nodeType":"项目划分","parentId":"{1DD3426E-A17E-4FC9-B7B5-22543997388C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"FZSC","单位":"","取费表":"","合价":"0","名称":"辅助生产工程","备注":"","序号":"二","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812000000","路径":"建筑工程/辅助生产工程"},{"_id":"{E620E5AE-E29A-4547-9BCF-FE10C450A702}","nodeType":"项目划分","parentId":"{9ECE65BC-FD73-49BC-BE7A-3119ECD8923F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"辅助生产建筑","备注":"","序号":"1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812100000","路径":"建筑工程/辅助生产工程/辅助生产建筑"},{"_id":"{FAFE5637-A89F-4424-B188-09BDA496ABFF}","nodeType":"项目划分","parentId":"{E620E5AE-E29A-4547-9BCF-FE10C450A702}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"综合楼","备注":"","序号":"1.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812101000","路径":"建筑工程/辅助生产工程/辅助生产建筑/综合楼"},{"_id":"{CE00DF76-C106-4F45-BB70-B98FE4171904}","nodeType":"项目划分","parentId":"{FAFE5637-A89F-4424-B188-09BDA496ABFF}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.1.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812101100","路径":"建筑工程/辅助生产工程/辅助生产建筑/综合楼/一般土建"},{"_id":"{9BDD0C98-A742-44E7-A2B8-7AFA3C97F840}","nodeType":"项目划分","parentId":"{FAFE5637-A89F-4424-B188-09BDA496ABFF}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"给排水","备注":"","序号":"1.1.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812101200","路径":"建筑工程/辅助生产工程/辅助生产建筑/综合楼/给排水"},{"_id":"{38386F44-E2E1-4E4D-9897-B3309D64D59C}","nodeType":"项目划分","parentId":"{FAFE5637-A89F-4424-B188-09BDA496ABFF}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.1.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812101300","路径":"建筑工程/辅助生产工程/辅助生产建筑/综合楼/采暖、通风及空调"},{"_id":"{94E0BB5D-B354-422E-BF36-908C37C3782B}","nodeType":"项目划分","parentId":"{FAFE5637-A89F-4424-B188-09BDA496ABFF}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.1.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812101400","路径":"建筑工程/辅助生产工程/辅助生产建筑/综合楼/照明"},{"_id":"{B229C72D-C7C2-45EF-A30A-5FD6AFF4B9B7}","nodeType":"项目划分","parentId":"{E620E5AE-E29A-4547-9BCF-FE10C450A702}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"检修备品库","备注":"","序号":"1.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812102000","路径":"建筑工程/辅助生产工程/辅助生产建筑/检修备品库"},{"_id":"{6C692607-D4E6-4094-9017-911A8EF03886}","nodeType":"项目划分","parentId":"{B229C72D-C7C2-45EF-A30A-5FD6AFF4B9B7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.2.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812102100","路径":"建筑工程/辅助生产工程/辅助生产建筑/检修备品库/一般土建"},{"_id":"{30B7A7FB-6314-41D8-918E-AC8F15525417}","nodeType":"项目划分","parentId":"{B229C72D-C7C2-45EF-A30A-5FD6AFF4B9B7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"给排水","备注":"","序号":"1.2.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812102200","路径":"建筑工程/辅助生产工程/辅助生产建筑/检修备品库/给排水"},{"_id":"{697C17CF-B915-41CB-B981-E85FBA0727E7}","nodeType":"项目划分","parentId":"{B229C72D-C7C2-45EF-A30A-5FD6AFF4B9B7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.2.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812102300","路径":"建筑工程/辅助生产工程/辅助生产建筑/检修备品库/采暖、通风及空调"},{"_id":"{6B6D1B29-05A3-4006-9483-95992644818F}","nodeType":"项目划分","parentId":"{B229C72D-C7C2-45EF-A30A-5FD6AFF4B9B7}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.2.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812102400","路径":"建筑工程/辅助生产工程/辅助生产建筑/检修备品库/照明"},{"_id":"{BB09870C-51C6-42FA-96A4-92FA0D7C81F9}","nodeType":"项目划分","parentId":"{E620E5AE-E29A-4547-9BCF-FE10C450A702}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"警卫室","备注":"","序号":"1.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812103000","路径":"建筑工程/辅助生产工程/辅助生产建筑/警卫室"},{"_id":"{A022F9ED-F664-4248-8FBD-9FB5F5782F7B}","nodeType":"项目划分","parentId":"{BB09870C-51C6-42FA-96A4-92FA0D7C81F9}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812103100","路径":"建筑工程/辅助生产工程/辅助生产建筑/警卫室/一般土建"},{"_id":"{31C4B6DB-7542-407A-8B7D-7603089ABC40}","nodeType":"项目划分","parentId":"{BB09870C-51C6-42FA-96A4-92FA0D7C81F9}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"给排水","备注":"","序号":"1.3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812103200","路径":"建筑工程/辅助生产工程/辅助生产建筑/警卫室/给排水"},{"_id":"{417FD706-37BD-4EDB-B19A-F8D3B4EE1E2B}","nodeType":"项目划分","parentId":"{BB09870C-51C6-42FA-96A4-92FA0D7C81F9}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812103300","路径":"建筑工程/辅助生产工程/辅助生产建筑/警卫室/采暖、通风及空调"},{"_id":"{8515C4B5-3FA8-497E-B692-71E809A34776}","nodeType":"项目划分","parentId":"{BB09870C-51C6-42FA-96A4-92FA0D7C81F9}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.3.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812103400","路径":"建筑工程/辅助生产工程/辅助生产建筑/警卫室/照明"},{"_id":"{55A105A4-E3CC-48A6-BF38-BB8CFA8F91AB}","nodeType":"项目划分","parentId":"{E620E5AE-E29A-4547-9BCF-FE10C450A702}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"雨水泵房","备注":"","序号":"1.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812104000","路径":"建筑工程/辅助生产工程/辅助生产建筑/雨水泵房"},{"_id":"{1E6CBCBB-0C39-4DF6-9D5E-18DEF6E93246}","nodeType":"项目划分","parentId":"{55A105A4-E3CC-48A6-BF38-BB8CFA8F91AB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.4.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812104100","路径":"建筑工程/辅助生产工程/辅助生产建筑/雨水泵房/一般土建"},{"_id":"{DB69F61A-004C-458D-A8C5-045D75829CAB}","nodeType":"项目划分","parentId":"{55A105A4-E3CC-48A6-BF38-BB8CFA8F91AB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"设备及管道","备注":"","序号":"1.4.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812104200","路径":"建筑工程/辅助生产工程/辅助生产建筑/雨水泵房/设备及管道"},{"_id":"{2D975957-BD89-4C99-BE53-3BEA0D0B13C3}","nodeType":"项目划分","parentId":"{55A105A4-E3CC-48A6-BF38-BB8CFA8F91AB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖及通风","备注":"","序号":"1.4.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812104300","路径":"建筑工程/辅助生产工程/辅助生产建筑/雨水泵房/采暖及通风"},{"_id":"{D77F9D0C-C761-4F86-8370-188E4190AC1E}","nodeType":"项目划分","parentId":"{55A105A4-E3CC-48A6-BF38-BB8CFA8F91AB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.4.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812104400","路径":"建筑工程/辅助生产工程/辅助生产建筑/雨水泵房/照明"},{"_id":"{8CAB7718-F2B8-4F84-B1E5-8045DB9956DE}","nodeType":"项目划分","parentId":"{E620E5AE-E29A-4547-9BCF-FE10C450A702}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"","合价":"0","名称":"车库","备注":"","序号":"1.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812105000","路径":"建筑工程/辅助生产工程/辅助生产建筑/车库"},{"_id":"{3A2B13AA-B8F6-4BF5-95FD-DE1A24A20763}","nodeType":"项目划分","parentId":"{8CAB7718-F2B8-4F84-B1E5-8045DB9956DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"一般土建","备注":"","序号":"1.5.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812105100","路径":"建筑工程/辅助生产工程/辅助生产建筑/车库/一般土建"},{"_id":"{F2DB627B-F686-42FE-83B7-159BD2537402}","nodeType":"项目划分","parentId":"{8CAB7718-F2B8-4F84-B1E5-8045DB9956DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"给排水","备注":"","序号":"1.5.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812105200","路径":"建筑工程/辅助生产工程/辅助生产建筑/车库/给排水"},{"_id":"{14982A1F-A295-4EFD-AE48-E215DD5B3AC6}","nodeType":"项目划分","parentId":"{8CAB7718-F2B8-4F84-B1E5-8045DB9956DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"采暖、通风及空调","备注":"","序号":"1.5.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812105300","路径":"建筑工程/辅助生产工程/辅助生产建筑/车库/采暖、通风及空调"},{"_id":"{7E65F508-99E5-4739-BCB7-759D23C7E01B}","nodeType":"项目划分","parentId":"{8CAB7718-F2B8-4F84-B1E5-8045DB9956DE}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"照明","备注":"","序号":"1.5.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812105400","路径":"建筑工程/辅助生产工程/辅助生产建筑/车库/照明"},{"_id":"{B0C731D7-6B13-4B1D-80CB-6161E07D9DDB}","nodeType":"项目划分","parentId":"{9ECE65BC-FD73-49BC-BE7A-3119ECD8923F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"站区性建筑","备注":"","序号":"2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812200000","路径":"建筑工程/辅助生产工程/站区性建筑"},{"_id":"{1ABAC6C5-F0FC-4C3C-9225-624ADF5BD2D1}","nodeType":"项目划分","parentId":"{B0C731D7-6B13-4B1D-80CB-6161E07D9DDB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"CDPZ","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"场地平整","备注":"","序号":"2.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812201000","路径":"建筑工程/辅助生产工程/站区性建筑/场地平整"},{"_id":"{3F0B2DAF-1B0A-4592-BFEB-1F7E1C96482E}","nodeType":"项目划分","parentId":"{B0C731D7-6B13-4B1D-80CB-6161E07D9DDB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"建筑取费表","合价":"0","名称":"站区道路及广场","备注":"","序号":"2.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812202000","路径":"建筑工程/辅助生产工程/站区性建筑/站区道路及广场"},{"_id":"{73790953-688A-4B5D-8ADB-42D3C343FC6E}","nodeType":"项目划分","parentId":"{B0C731D7-6B13-4B1D-80CB-6161E07D9DDB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"站区排水","备注":"","序号":"2.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812203000","路径":"建筑工程/辅助生产工程/站区性建筑/站区排水"},{"_id":"{4B447012-53FF-4EF3-A056-31E367CD071F}","nodeType":"项目划分","parentId":"{73790953-688A-4B5D-8ADB-42D3C343FC6E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m","取费表":"建筑取费表","合价":"0","名称":"排水管道","备注":"","序号":"2.3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812203100","路径":"建筑工程/辅助生产工程/站区性建筑/站区排水/排水管道"},{"_id":"{79D02485-AA04-482D-9869-8C65DC6438C8}","nodeType":"项目划分","parentId":"{73790953-688A-4B5D-8ADB-42D3C343FC6E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"排水设施","备注":"","序号":"2.3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812203200","路径":"建筑工程/辅助生产工程/站区性建筑/站区排水/排水设施"},{"_id":"{03143546-8D53-48D7-9C4B-127038462D87}","nodeType":"项目划分","parentId":"{73790953-688A-4B5D-8ADB-42D3C343FC6E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"污水处理装置","备注":"","序号":"2.3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812203300","路径":"建筑工程/辅助生产工程/站区性建筑/站区排水/污水处理装置"},{"_id":"{9178002E-1150-4F8F-9F14-C4A515445C1E}","nodeType":"项目划分","parentId":"{73790953-688A-4B5D-8ADB-42D3C343FC6E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"污水调节水池","备注":"","序号":"2.3.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812203400","路径":"建筑工程/辅助生产工程/站区性建筑/站区排水/污水调节水池"},{"_id":"{DE566F76-975E-44D5-A5B1-F2E80FF43730}","nodeType":"项目划分","parentId":"{B0C731D7-6B13-4B1D-80CB-6161E07D9DDB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"站区环保隔声降噪","备注":"","序号":"2.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812204000","路径":"建筑工程/辅助生产工程/站区性建筑/站区环保隔声降噪"},{"_id":"{8CA65820-6D17-4E70-9C83-436D44067487}","nodeType":"项目划分","parentId":"{B0C731D7-6B13-4B1D-80CB-6161E07D9DDB}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m","取费表":"建筑取费表","合价":"0","名称":"围墙及大门","备注":"","序号":"2.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812205000","路径":"建筑工程/辅助生产工程/站区性建筑/围墙及大门"},{"_id":"{2B1D1E58-4A87-4BC5-9237-255E58CCDC2E}","nodeType":"项目划分","parentId":"{9ECE65BC-FD73-49BC-BE7A-3119ECD8923F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"TSGZW","单位":"","取费表":"","合价":"0","名称":"特殊构筑物","备注":"","序号":"3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812300000","路径":"建筑工程/辅助生产工程/特殊构筑物"},{"_id":"{1FD5B6A2-8A64-4EB5-813F-2365BC933F1D}","nodeType":"项目划分","parentId":"{2B1D1E58-4A87-4BC5-9237-255E58CCDC2E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"挡土墙及挡水墙","备注":"","序号":"3.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812301000","路径":"建筑工程/辅助生产工程/特殊构筑物/挡土墙及挡水墙"},{"_id":"{B0A86916-F87A-4E69-8789-40152304B575}","nodeType":"项目划分","parentId":"{2B1D1E58-4A87-4BC5-9237-255E58CCDC2E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m","取费表":"建筑取费表","合价":"0","名称":"防洪排水沟","备注":"","序号":"3.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812302000","路径":"建筑工程/辅助生产工程/特殊构筑物/防洪排水沟"},{"_id":"{99A9C1E1-0A92-45D9-A88F-0B135DE6885C}","nodeType":"项目划分","parentId":"{2B1D1E58-4A87-4BC5-9237-255E58CCDC2E}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"建筑取费表","合价":"0","名称":"护坡","备注":"","序号":"3.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812303000","路径":"建筑工程/辅助生产工程/特殊构筑物/护坡"},{"_id":"{7E4568A7-25A6-4301-B910-69F29E15D59F}","nodeType":"项目划分","parentId":"{9ECE65BC-FD73-49BC-BE7A-3119ECD8923F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/个","取费表":"建筑取费表","合价":"0","名称":"全站沉降观测点","备注":"","序号":"4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812400000","路径":"建筑工程/辅助生产工程/全站沉降观测点"},{"_id":"{5A32EAE3-D27E-4862-BB0A-1EEE07184687}","nodeType":"项目划分","parentId":"{9ECE65BC-FD73-49BC-BE7A-3119ECD8923F}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"建筑取费表","合价":"0","名称":"站区绿化","备注":"","序号":"5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21812500000","路径":"建筑工程/辅助生产工程/站区绿化"},{"_id":"{58A28185-E20F-44FF-B871-F1715679DD1D}","nodeType":"项目划分","parentId":"{1DD3426E-A17E-4FC9-B7B5-22543997388C}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"DXGC","单位":"","取费表":"","合价":"0","名称":"与站址有关的单项工程","备注":"","序号":"三","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813000000","路径":"建筑工程/与站址有关的单项工程"},{"_id":"{7CB18BF3-7959-4012-8994-C89EEEB131F9}","nodeType":"项目划分","parentId":"{58A28185-E20F-44FF-B871-F1715679DD1D}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"DJCL","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"地基处理","备注":"","序号":"1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813100000","路径":"建筑工程/与站址有关的单项工程/地基处理"},{"_id":"{5A711814-7043-4F3E-B704-F0B2E5C55345}","nodeType":"项目划分","parentId":"{58A28185-E20F-44FF-B871-F1715679DD1D}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m","取费表":"","合价":"0","名称":"站外道路","备注":"","序号":"2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813200000","路径":"建筑工程/与站址有关的单项工程/站外道路"},{"_id":"{B8E0BACC-F7A5-45AF-89E3-D858861BC7BC}","nodeType":"项目划分","parentId":"{5A711814-7043-4F3E-B704-F0B2E5C55345}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"建筑取费表","合价":"0","名称":"道路路面","备注":"","序号":"2.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813201000","路径":"建筑工程/与站址有关的单项工程/站外道路/道路路面"},{"_id":"{1BB2A19C-FC28-4127-BA1F-DE53CD1B6F53}","nodeType":"项目划分","parentId":"{5A711814-7043-4F3E-B704-F0B2E5C55345}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"TSF","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"土石方","备注":"","序号":"2.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813202000","路径":"建筑工程/与站址有关的单项工程/站外道路/土石方"},{"_id":"{A8CDA2D8-8850-4F87-9C99-4BA68D6568AA}","nodeType":"项目划分","parentId":"{5A711814-7043-4F3E-B704-F0B2E5C55345}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m³","取费表":"建筑取费表","合价":"0","名称":"挡土墙","备注":"","序号":"2.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813203000","路径":"建筑工程/与站址有关的单项工程/站外道路/挡土墙"},{"_id":"{2589AFE5-70A6-4EF6-8BF7-F04119B56801}","nodeType":"项目划分","parentId":"{5A711814-7043-4F3E-B704-F0B2E5C55345}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"元/m²","取费表":"建筑取费表","合价":"0","名称":"护坡","备注":"","序号":"2.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813204000","路径":"建筑工程/与站址有关的单项工程/站外道路/护坡"},{"_id":"{B3829DB9-5D32-4D77-BBBC-D3EF5FB73C50}","nodeType":"项目划分","parentId":"{5A711814-7043-4F3E-B704-F0B2E5C55345}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"桥涵","备注":"","序号":"2.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813205000","路径":"建筑工程/与站址有关的单项工程/站外道路/桥涵"},{"_id":"{F73C5F57-0829-4A33-8B34-268F4D51F767}","nodeType":"项目划分","parentId":"{5A711814-7043-4F3E-B704-F0B2E5C55345}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"排水沟","备注":"","序号":"2.6","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813206000","路径":"建筑工程/与站址有关的单项工程/站外道路/排水沟"},{"_id":"{D285353D-9C32-455A-8332-7C1BB3D25833}","nodeType":"项目划分","parentId":"{58A28185-E20F-44FF-B871-F1715679DD1D}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"站外水源","备注":"","序号":"3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813300000","路径":"建筑工程/与站址有关的单项工程/站外水源"},{"_id":"{82D9A542-EC8F-4577-B284-680B60AF1BA0}","nodeType":"项目划分","parentId":"{58A28185-E20F-44FF-B871-F1715679DD1D}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"站外排水","备注":"","序号":"4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813400000","路径":"建筑工程/与站址有关的单项工程/站外排水"},{"_id":"{4E7641B9-6595-47EF-83E0-C2B1E2972D3C}","nodeType":"项目划分","parentId":"{58A28185-E20F-44FF-B871-F1715679DD1D}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"站外蒸发池","备注":"","序号":"5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813500000","路径":"建筑工程/与站址有关的单项工程/站外蒸发池"},{"_id":"{9FDFA5F0-E706-4454-B07E-7F10B3AB4C07}","nodeType":"项目划分","parentId":"{58A28185-E20F-44FF-B871-F1715679DD1D}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"施工降水","备注":"","序号":"6","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813600000","路径":"建筑工程/与站址有关的单项工程/施工降水"},{"_id":"{5F7C9F9C-4E03-453F-8CF9-33F61D320D63}","nodeType":"项目划分","parentId":"{58A28185-E20F-44FF-B871-F1715679DD1D}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"","合价":"0","名称":"临时工程","备注":"","序号":"7","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813700000","路径":"建筑工程/与站址有关的单项工程/临时工程"},{"_id":"{9E3556AF-3D56-4D88-8161-1EFE1B8EF14E}","nodeType":"项目划分","parentId":"{5F7C9F9C-4E03-453F-8CF9-33F61D320D63}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"临时施工电源","备注":"","序号":"7.1","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813701000","路径":"建筑工程/与站址有关的单项工程/临时工程/临时施工电源"},{"_id":"{40F0AE79-F16A-4A84-94E5-6A4718B57E10}","nodeType":"项目划分","parentId":"{5F7C9F9C-4E03-453F-8CF9-33F61D320D63}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"临时施工水源","备注":"","序号":"7.2","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813702000","路径":"建筑工程/与站址有关的单项工程/临时工程/临时施工水源"},{"_id":"{0E5BC86B-3907-4C07-B9F6-89C98A6E3EEA}","nodeType":"项目划分","parentId":"{5F7C9F9C-4E03-453F-8CF9-33F61D320D63}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"临时施工道路","备注":"","序号":"7.3","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813703000","路径":"建筑工程/与站址有关的单项工程/临时工程/临时施工道路"},{"_id":"{06C0B50F-D8F1-4C2E-A285-E0B2C7B85CAF}","nodeType":"项目划分","parentId":"{5F7C9F9C-4E03-453F-8CF9-33F61D320D63}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"临时施工通信线路","备注":"","序号":"7.4","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813704000","路径":"建筑工程/与站址有关的单项工程/临时工程/临时施工通信线路"},{"_id":"{67108085-B622-4DDD-B4D1-1BC4419E896E}","nodeType":"项目划分","parentId":"{5F7C9F9C-4E03-453F-8CF9-33F61D320D63}","relTbId":"{CF175ECC-702A-40C5-95A6-C55AE2605068}","专业类型":"变电建筑","人工调差系数":"10.18","代码":"","单位":"","取费表":"建筑取费表","合价":"0","名称":"临时施工防护工程","备注":"","序号":"7.5","拆除人工调差系数":"8.96","拆除机械调差系数":"0","拆除材料调差系数":"0","数量":"","机械调差系数":"0","材料调差系数":"0","编码":"","计算式":"","费率":"0","费用编码":"21813705000","路径":"建筑工程/与站址有关的单项工程/临时工程/临时施工防护工程"}]}}
|